Radial Leaded PTC Resettable Fuse: FRV Series Preliminary
1. Summary
(a) RoHS Compliant (Lead Free) Product (b) Applications: Line Voltage Power Supply, Transformer and Appliances (c) Product Features: Low hold current, Solid state, Radial leaded product ideal for up to 265VAC/DC (d) Operation Current: 50mA~550mA (e) Maximum Operating Voltage: 240VAC/DC (f) Maximum Interrupt Voltage: 265VAC/DC (g) Temperature Range : -40℃ to 85℃
2. Agency Recognition
UL: File No. Pending C-UL: File No. Pending TÜV: File No. Pending
. 3. Electrical Characteristics (23℃)
Part Number
FRV005-240F FRV008-240F FRV012-240F FRV016-240F FRV025-240F FRV033-240F FRV040-240F FRV055-240F
Hold Trip Max.Time Maximum Rated Typical Current Current to Trip Current Voltage Power IH, A
0.05 0.08 0.12 0.16 0.25 0.33 0.40 0.55
Resistance Tolerance RMIN
ohms 18.50 7.40 3.00 2.50 1.30 0.83 0.60 0.45
R1MAX
ohms 65.00 26.00 12.00 7.80 3.80 2.60 1.90 1.45
IT, A
0.12 0.19 0.30 0.37 0.56 0.74 0.90 1.25
at 5xIH 15.0 15.0 15.0 15.0 18.5 18.5 24.0 26.0
IMAX, A
1.0 1.2 1.2 2.0 3.5 4.5 5.5 7.0
VMAX, VAC Pd, W
240 240 240 240 240 240 240 240 0.70 0.80 1.00 1.40 1.50 1.70 2.00 3.40
IH=Hold current-maximum current at which the device will not trip at 23 ℃ still air. IT=Trip current-minimum current at which the device will always trip at 23 ℃ still air. V MAX=Maximum voltage device can withstand without damage at its rated current. I MAX= Maximum fault current device can withstand without damage at rated voltage (V MAX). Pd=Typical power dissipated from device when in tripped state in 23 ℃ still air environment. RMIN=Minimum device resistance at 23 ℃. R1MAX=Maximum device resistance at 23 ℃, 1 hour after tripping. Physical specifications: Lead material: FRV005-240F~FRV016-240F Tin plated copper, 24AWG. FRV025-240F~FRV040-240F Tin plated copper, 22AWG. FRV055-240F Tin plated copper, 20AWG. Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement.
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
www.DataSheet.in
NO.
PQ24-101E 3 Page
2/4
Product Specification and Approval Sheet Version
4. Production Dimensions (millimeter)
FRV 005-240F~FRV016-240F Lead Size: 24AWG Φ 0.51 mm Diameter
FRV025-240F~FRV040-240F Lead Size: 22AWG Φ 0.65 mm Diameter
FRV055-240F Lead Size: 20AWG Φ 0.81 mm Diameter
Part A Number Maximum FRV005-240F 8.3 FRV008-240F 8.3 FRV012-240F 8.3 FRV016-240F 9.9 FRV025-240F 9.6 FRV033-240F 11.4 FRV040-240F 11.5 FRV055-240F 14.0
B Maximum 10.7 10.7 10.7 12.5 17.4 16.5 19.5 21.7
C Typical 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1
D Minimum 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6
E Maximum 3.8 3.8 3.8 3.8 3.8 3.8 3.8 4.1
5. Thermal Derating Curve
Thermal Derating Curve - FRV Series
200%
Precent of Rated Hold and Trip Current
150%
100%
50%
0% -20
0
20
40
60
80
Ambient Temperature (C)
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
www.DataSheet.in
NO.
PQ24-101E 3 Page
3/4
Product Specification and Approval Sheet Version
6. Typical Time-To-Trip at 23℃
A= FRV005-240F B= FRV008-240F C= FRV012-240F D= FRV016-240F E= FRV025-240F F= FRV033-240F G= FRV040-240F H= FRV055-240F
Time-to-trip (S)
10 100 1000
C A B
D
E
F
G
H
1
0.1
0.01 0.1 1 10
Fault current (A)
7. Material Specification
Lead material:FRV005-240F~FRV016-240F Tin plated copper, 24AWG. FRV025-240F~FRV040-240F Tin plated copper, 22AWG. FRV055-240F Tin plated copper, 20AWG. Soldering characteristics: MIL-STD-202, Method 208E. Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement.
8. Part Numbering and Marking System
Part Numbering System
FRV □ □ □ - □ □ □ F RoHS Compliant / Lead Free Voltage rating Current rating F RV12F 41AB □
Example
Part Marking System
F RV □ □ F Logo RoHS Compliant / Lead Free Part Identification Product Family □ □ □ Date Code/Lot Number
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
www.DataSheet.in
NO.
PQ24-101E 3 Page
4/4
Product Specification and Approval Sheet Version
Warning: - Each product should be carefully evaluated and tested for their suitability of application.
- Operation beyond the specified maximum rating or improper use may result in damage and possible electrical arcing and/or flame. - PPTC device are intended for occasional overcurrent protection. Application for repeated overcurrent condition and/or prolonged trip are not anticipated. - Avoid contact of PPTC device with chemical solvent, including some inert material such as silicone based oil, lubricant and etc. Prolonged contact will damage the device performance. - Additional protection mechanism are strongly recommended to be used in conjunction with the PPTC device for protection against abnormal or failure conditions. -.