REED SWITCH
I/SEC/AI03-001/A/26/05/2000
page 1 / 2 F/GB
INTERRUPTEUR REED REED SWITCH NORMALEMENT OUVERT, CONTACT SEC NORMALY OPEN...
Description
I/SEC/AI03-001/A/26/05/2000
page 1 / 2 F/GB
INTERRUPTEUR REED REED SWITCH NORMALEMENT OUVERT, CONTACT SEC NORMALY OPEN, DRY CONTACT
Ø 1,8 max
AI03 . . . .
Ø 0,5
10 max 46
CARACTERISTIQUES ELECTRIQUES / ELECTRICAL DATA Puissance maxi commutable / Max. switching power Tension maxi commutable / Max. switching voltage Courant maxi commutable / Max. switching current Courant de travail / Carrying current Tension typique de tenue / Typical dielectric strength Résistance de contact initiale ( max ) / Initial contact resistance Méthode de mesure / Test process Bobine / Coil : Mesure en 4 points /4 points measurement I = 10 mA ; U = 2 V Alimentation de bobine /Coil voltage: ATF + 20 % 10 W 200 Vdc 0,5 A 0,75 A 250 Vdc ≤ 125 mΩ
mesure de tension voltage measurement
30 mm
Résistance d'isolement ( min ) / Insulation resistance Capacité / Capacitance Fréquence de résonnance / Resonnant frequency
www.DataSheet4U.com
106 Ω 0,25 pF 11,1 KHz
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis.
r
celduc
e l a i
s
I/SEC/AI03-001/A/26/05/2000
page 2 / 2 F/GB
Temps de commutation maximum Méthode de mesure / Test process ---> Alimentation de bobine /Coil voltage: ATF + 50% à l'action ( rebonds inclus ) / max. operate time ( bounces included ) 0,5 ms au relâchement / max. release time 0,05 ms CARACTERISTIQUES PHYSIQUES / PHYSICAL DATA Matériau utilisé pour le contact / Contact materi...