RF AMPLIFIER
RF AMPLIFIER MODEL TM3094
Features
! ! ! ! Low +5 Volt Operation High Gain: 19.5 dB Typical Operating Temp. - 55 ºC to +...
Description
RF AMPLIFIER MODEL TM3094
Features
! ! ! ! Low +5 Volt Operation High Gain: 19.5 dB Typical Operating Temp. - 55 ºC to +85 ºC Environmental Screening Available
Available as:
TM3094, 4 Pin TO-8 (T4) TN3094, 4 Pin Surface Mount (SM3) FP3094, 4 Pin Flatpack (FP4) BX3094, Connectorized Housing (H1)
Typical Intermodulation Performance at 25 º C
Second Order Harmonic Intercept Point ....... +52 dBm (Typ.) Second Order Two Tone Intercept Point ........ +46 dBm (Typ.) Third Order Two Tone Intercept Point ............ +27 dBm (Typ.)
Specifications
CHARACTERISTIC Frequency Gain (dB) Power @ 1 dB Comp. (dBm) Reverse Isolation (dB) VSWR In Out Noise Figure (dB) Power Vdc mA TYPICAL Ta= 25 ºC 50 - 2000 MHz 19.5 +14 -35 1.8:1 1.8:1 4.0 +5 70 MIN/MAX Ta = -55 ºC to +85 ºC 50 - 2000 MHz 18 Min. +12 Min. -30 Max. 2.0:1 Max. 2.0:1 Max. 6.0 Max. +5 75 Max.
Maximum Ratings
Ambient Operating Temperature .............. -55ºC to + 100 ºC Storage Temperature ............................... -62ºC to + 125 ºC Case Temperature ................................................. + 125 ºC DC Voltage ........................................................... + 8 Volts Continuous RF Input Power .................................. +13 dBm Short Term RF Input Power ...... 50 Milliwatts (1 Minute Max.) Maximum Peak Power .................... 0.2 Watt (3 µsec Max.)
Note: Care should always be taken to effectively ground the case of each unit.
Typical Performance Data
Gain (dB)
22 21 20 19 18
Start 50 MHz ...