DatasheetsPDF.com

30-GC6NLT1 Dataheets PDF



Part Number 30-GC6NLT1
Manufacturers MTU Onsite Energy
Logo MTU Onsite Energy
Description GAS ENGINE-GENERATOR SET
Datasheet 30-GC6NLT1 Datasheet30-GC6NLT1 Datasheet (PDF)

A tognum Group Brand GAS Engine-Generator Set 30-GC6NLT1 30 ekW  60 Hz  Standby /  /  208 - 600V System Ratings Standby Voltage (L-L) Phase PF Hz Natural Gas Ratings: Amps Natural Gas Ratings: kW/kVA LP Gas Ratings: Amps LP Gas Ratings: kW/kVA skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V** 1 1.0 60 117 28/28 125 30/30 70 284CSL1508 130°C/27°C 12 LEAD ZIG-ZAG 240V** 1 1.0 60 117 28/28 125 30/30 63 283CSL1517 125°C/40°C 4 LEAD 208V** 3.

  30-GC6NLT1   30-GC6NLT1


Document
A tognum Group Brand GAS Engine-Generator Set 30-GC6NLT1 30 ekW  60 Hz  Standby /  /  208 - 600V System Ratings Standby Voltage (L-L) Phase PF Hz Natural Gas Ratings: Amps Natural Gas Ratings: kW/kVA LP Gas Ratings: Amps LP Gas Ratings: kW/kVA skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V** 1 1.0 60 117 28/28 125 30/30 70 284CSL1508 130°C/27°C 12 LEAD ZIG-ZAG 240V** 1 1.0 60 117 28/28 125 30/30 63 283CSL1517 125°C/40°C 4 LEAD 208V** 3 0.8 60 104 30/37.5 104 30/37.5 70 283CSL1507 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 90 30/37.5 90 30/37.5 70 283CSL1507 130°C/27°C 12 LEAD HI DELTA 480V** 3 0.8 60 45 30/37.5 45 30/37.5 90 283CSL1507 130°C/27°C 12 LEAD HI WYE 600V** 3 0.8 60 36 30/37.5 36 30/37.5 122 284PSL1752 125°C/40°C 4 LEAD WYE * The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered Facts Engine-Generator Set Tested to ISO 8528-5 for Transient Response //  UL2200, CSA Listing Offered //  Accepts Rated Load in One Step Per NFPA 110, Level 1 //  All engine-generator sets are prototype and factory tested //  MTU Onsite Energy is a single source supplier //  Global Product Support //  2 Year Standard Warranty //  Custom Design for Any Application //  3.0 L Engine www.DataSheet4U.com - 3.0 Liter Displacement - 4-Cycle //  Integral Vibration Isolators //  //  //  //  //  Complete Range of Accessories Permanent Magnet Generator (PMG) - Optional - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings Digital Control Panel(s) - UL Recognized, , NFPA 110 - Complete System Metering - LCD Display Cooling System - Integral Set-Mounted - Engine Driven Fan 2 // /  / 30-GC6NLT1 STANDARD EQUIPMENT //  Engine //  Digital Control Panel(s) Air Cleaner Oil Pump Full Flow Oil Filter Jacket Water Pump Thermostat Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 12V Governor – Electric Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 12V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator 16 Programmable Contact Inputs 7 Contact Outputs UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Level Compatible //  Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 130°C Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing ±.25% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content www.DataSheet4U.com 3 // /  / 30-GC6NLT1 Application data //  Engine GM 3.0L 4-Cycle 4-Inline 181 (3) 4 (10.2) 3.6 (9.1) 9.25:1 1,800 Bosch 51.5 (38.4) ±1% 60 Hz Dry //  Fuel Consumption (NG-1000 BTU/ft3 / LP-2500 BTU/ft3) NG 361 (10.2) 270 (7.7) 189 (5.4) LPG 159 (4.5) 120 (3.4) 84 (2.4) Manufacturer Model Type Arrangement Displacement: Cu In (lit) Bore: in (cm) Stroke: in (cm) Compression Ratio Rated RPM Engine Governor Max Power: Standby: bhp (kWm) Speed Regulation Frequency Air Cleaner At 100% of Power Rating: ft3/hr (m3/hr) At 75% of Power Rating: ft3/hr (m3/hr) At 50% of Power Rating: ft3/hr (m3/hr) //  Cooling - Radiator System Ambient Capacity of Radiator: °F (°C) 122 (50) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: in. H20 (kPa) 0.5 (0.12) Water Pump Capacity: gpm (lit/min) 17 (64.4) Heat Rejection to Coolant: BTUM (kW) 1,436 (25.3) Heat Radiated to Ambient: BTUM (kW) 886 (15.6) //  Liquid Capacity (Lubrication) 1.3 (4.9) 1 (3.8) 3.9 (14.8) //  Air Requirements Total Oil System: gal (lit) Engine Jacket Water Capacity: gal (lit) System Coolant Capacity: gal (lit) //  Electrical 12 600 Aspirating: *SCFM (m3/min) 94.3 (2.7) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) 2,882.39 (81.6) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise *SCFM: (m3/min) 1,998 (56.6) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) Electric Volts DC Cold Cranking Amps Under 0°F (-17.8°C) //  //  Fuel Inlet 3/4” NPT 7–11 (178–279) Exhaust System Fuel Supply Connection Size Fuel Supply Pressure: in. H20 (mm H20) Gas Temp. (Stack): °F .


2800-XC6DT2 30-GC6NLT1 30-JC6DT4


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)