DatasheetsPDF.com

30-JS6DT4 Dataheets PDF



Part Number 30-JS6DT4
Manufacturers MTU Onsite Energy
Logo MTU Onsite Energy
Description DIESEL ENGINE-GENERATOR SET
Datasheet 30-JS6DT4 Datasheet30-JS6DT4 Datasheet (PDF)

A tognum Group Brand Diesel Engine-Generator Set 30-JS6DT4 30 ekW / 60 Hz / Standby 208 - 600V System Ratings Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model Temp Rise Connection ** UL2200 Offered 240V** 1 1.0 60 30 30 125 64 284CSL1542 130°C/27°C 12 LEAD ZIG-ZAG 208V** 3 0.8 60 30 37.5 104 85 284CSL1542 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 30 37.5 90 85 284CSL1542 130°C/27°C 12 LEAD HI DELTA 480V** 3 0..

  30-JS6DT4   30-JS6DT4


Document
A tognum Group Brand Diesel Engine-Generator Set 30-JS6DT4 30 ekW / 60 Hz / Standby 208 - 600V System Ratings Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model Temp Rise Connection ** UL2200 Offered 240V** 1 1.0 60 30 30 125 64 284CSL1542 130°C/27°C 12 LEAD ZIG-ZAG 208V** 3 0.8 60 30 37.5 104 85 284CSL1542 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 30 37.5 90 85 284CSL1542 130°C/27°C 12 LEAD HI DELTA 480V** 3 0.8 60 30 37.5 45 85 284CSL1542 130°C/27°C 12 LEAD HI WYE 600V** 3 0.8 60 30 37.5 36 123 284CSL1542 125°C/40°C 4 LEAD WYE Facts EPA Tier 4 Certified Engine-Generator Set Tested to ISO 8528-5 for Transient Response //  UL2200, CSA Listing Offered //  Accepts Rated Load in One Step Per NFPA 110, Level 1 //  All engine-generator sets are prototype and factory tested //  MTU Onsite Energy is a single source supplier www.DataSheet4U.com //  Global Product Support //  2 Year Standard Warranty //  4024TF281 Diesel Engine - 2.4 Liter Displacement - 4-Cycle //  //  //  //  //  //  Complete Range of Accessories Permanent Magnet Generator (PMG) - Optional - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings Digital Control Panel(s) - UL Recognized, , NFPA 110 - Complete System Metering - LCD Display Cooling System - Integral Set-Mounted - Engine Driven Fan 2 // /  / 30-JS6DT4 STANDARD EQUIPMENT //  Engine //  Digital Control Panel(s) Air Cleaner Oil Pump Full Flow Oil Filter Jacket Water Pump Closed Crankcase Vent Thermostats Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 12V Governor – Electric Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 12V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator 16 Programmable Contact Inputs 7 Contact Outputs UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Level Compatible //  Additional Features //  Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 130°C Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing ±1% Voltage Regulation 100% of Rated Load - One Step www.DataSheet4U.com 3% Maximum Harmonic Content Oil Drain Extension & S/O Valve Flexible Fuel Connector Battery Cables Vibration Isolation Pads Jacket Water Heater: -20° F Mainline Circuit Breaker UL2200 Listed Steel Sub-Base Radiator Duct Flange (OPU) Lube Oil & Antifreeze Operator’s and Owner’s Manual 2 Year/3000 Hour Warranty Factory Tested at 0.8 PF (3 PH) //  Optional Features Battery Charger: 6 Amp or 10 Amp Battery: 12 Volt w/ Rack Circuit Breaker: Standard or 100% Muffler (OPU only) Sub-Base Fuel Tank w/ Electrical Stub-Up Area Weatherproof Enclosure Sound Attenuation - 1 1/2” Foam - Sound Scoops Remote Annunciator Isochronous Governor 3 // /  / 30-JS6DT4 Application data //  Engine John Deere 4024TF281 4-Cycle 4-Inline 149 (2.4) 3.4 (8.6) 4.1 (10.5) 20.5:1 1,800 Electric Isochronous 49 (36) ±1% 60 Hz Dry //  Fuel Consumption 2.8 (10.6) 2.1 (8) 1.4 (5.3) Manufacturer Model Type Arrangement Displacement: Cu In (lit) Bore: in (cm) Stroke: in (cm) Compression Ratio Rated RPM Engine Governor Max Power: Standby: bhp (kWm) Regulation Frequency Air Cleaner At 100% of Power Rating: gal/hr (lit/hr) At 75% of Power Rating: gal/hr( lit/hr) At 50% of Power Rating: gal/hr (lit/hr) //  Cooling - Radiator System 122 (50) 0.5 (0.12) 24 (91) 1,412 (25) 291 (5) Ambient Capacity of Radiator: °F (°C) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: in. H20 (kPa) Water Pump Capacity: gpm (lit/min) Heat Rejection to Coolant: BTUM (kW) Heat Radiated to Ambient: BTUM (kW) //  //  Liquid Capacity (Lubrication) 2.1 (8) 0.675 (2.6) 2.29 (8.7) Air Requirements 106 (3) 2,645 (75) Total Oil System: gal (lit) Engine Jacket Water Capacity: gal (lit) System Coolant Capacity: gal (lit) Aspirating: *SCFM (m3/min) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) 655 (19) //  Electrical 12 750 //  Electric Volts DC Cold Cranking Amps Under 0°F (-17.8°C).


30-JC6DT4 30-JS6DT4 300-JC6DT3


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)