VLT60 Series
Single and Triple Output 60W Universal Input AC/DC Power Supplies
Unless stated otherwise, specifications are typical and rated at full load, nominal input voltage, convection cooling and 25oC.
INPUT
AC Input Efficiency Input Frequency Input Current Inrush Current Auto-ranging 90 to 132V 180 to 264V 85% 47— 63 Hz 1.5Arms, max 75A, max
Full load at low line High line, cold start
Model Number
VLT60-1000 VLT60-1001 VLT60-1002 VLT60-1003 VLT60-1004 VLT60-3000
Output
V1 V1 V1 V1 V1 V1 V2 V3 V1 V2 V3 V1 V2 V3 V1 V2 V3
Voltage/ Current *
[email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]
Voltage Set Point
5.2V 12V 15V 24V 48V 5.2V 12.5V -12V 5.2V 23.8V -12V 5.2V 14.6V -15.5V 3.3V 5.2V -16.0V
Min. Load
0.2A 0.1A 0.1A 0.05A 0.03A 0.5A 0.1A 0.0A 0.5A 0.1A 0.0A 0.5A 0.1A 0.0A 0.5A 0.1A 0.0A
OUTPUT
Output Power VLT60-1000 VLT60-3003 Other models 115V/230V V1 V2 and V3 Low line to high line Min to 50% full load V1 V2 and V3 50% to full load Voltage deviation Recovery Time V1 only 5V V1 only 3.3V Primary limited V1 V2 and V3 All Outputs 50W max 45W max 60W max See table 6ms/10ms +3% +5% 0.3% +3% +5% 10%, max <5ms 6.2V,+0.4V 3.95V,+0.25V Yes, 130% Short Term 65mV 1% <100ms 0 to 50oC — 40 to 85oCC Convection 95%, max >200,000 hrs
Voltage Set Point Hold-Up Time Voltage Set Point Accuracy Line Regulation Load Regulation
VLT60-3001
VLT60-3002
Transient Response
VLT60-3003
OVP Overload Protection Ripple and Noise Output Rise Time
*Maximum current per output channel. Do not exceed total output power rating
Short Circuit Protection Auto recovery <6s
MECHANICAL
AC Input Connector J1 Molex 3 position, 0.156 center header 26-60-4030-P or equivalent Ground Connector Spade connector DC Output Connector J2 Molex 6 position, 0.156 center header 26-60-4060-P or equivalent Size 2x4x1.08 (50.8x101.6x27.4mm) Weight 5oz (150g)
ENVIRONMENTAL
Operating Temperature Storage Temperature Cooling Relative Humidity Non condensing MTBF MIL-HDBK-217F
EMC AND SAFETY
CE Mark EMC Agency Approvals Safety Standards Full compliance with the LVD EN55022-B, CISPR22-B, FCC Part 15 Class B, EN50082-1 VDE, UL, c-UL IEC950, EN60950, UL1950, CSA C22.2 No. 950 Class 1 SELV VDE: 18934-3336 UL: E150565
INPUT CONNECTOR J1 Pin 1 Pin 2 AC Neutral AC Line
OUTPUT CONNECTOR J2 Single Output Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 V1 V1 Common Common NC NC Triple Output V1 V1 Common Common V3 V2
Input Spade Connector GND AC Ground
www.DataSheet4U.com
Safety File numbers
Dimensions
4.00" [101.6mm] 3.75" [95.3mm] SMT component height 0.20" [5.1mm] Unit Height VLT25: 1.07" (27.2mm) VLT40: 1.07" (27.2mm) VLT60: 1.08" (27.4mm) MVLT25: 1.07" (27.2mm) MVLT40: 1.07" (27.2mm) MVLT60: 1.08" (27.4mm)
6
2.00" [50.8mm]
1 1 2
1.75" [44.5mm]
GND Mounting hole ø 0.16" [4.0mm] 4 places Clearance top to bottom ø 0.312" [7.9mm] 4 places
Unit Height
Cover Kit p/n VLT60CK
0.47" [12.0mm] Contents Mounting bracket Cover Insulator M3 fixing screws
2.36" [59.9mm]
4.32" [109.7mm] 1.22" [31.1mm]
1.18" [29.9mm]
3.7"[94.1mm]
VLT60CK Derating Guidelines VLT25/MVLT25: ambient >40oC, derate by 1.3W/oC to 50oC. 5CFM fan recommended to circulate air. VLT40/MVLT40: ambient >40oC, derate by 1.3W/oC to 50oC. 5CFM fan recommended to circulate air. VLT60/MVLT60: ambient >40oC, derate by 1.3W/oC to 50oC. 5CFM fan recommended to circulate air.
Output Power 70 W 60 W 50 W 40 W 30 W 20 W 10 W 0W 10 C
o
VLT60
-1. -1. -1. 3W
o / C
VLT40 www.DataSheet4U.com VLT25
3W 3W
/ C / C
20 C
o
30 C
o
40 C
o
50 C
o
Ambient Temperature
.