TPS20
TPS20 series
High-Reliability Pressure Transmitter
TPS20 Series(electric pressure transmitter) as high accuracy high reliable pressure transmitter using Stainless
steel diaphragm, is able to measure whole scale, 0.2~350 Kg/cm²G and has absolute pressure, 0~30Kg/Abs type.
Features
• Measuring for Air, Water, Oil, etc.
• A variety of model according to field application
- Head type
- Din connector type
- Connector cable type
• Adoption of suitable Stainless Steel Diaphragm for temperature
character
• 4~20mA transmission output by 2-wire
Ordering Codes
TPS20
Pressure G
Type
A
Type
1
Cable selection
2M, 5M
:
2
(Separate goods) 3
Range
mark is possible
for absolute
pressure
1
2
3
4
5
6
7
8
9
A
Description
Gauge Pressure
Absolute Pressure
Head Type
Pressure Transmitter
Pressure Type
Connector Type
Pressure range
Process Connection
Din Connector Type
Connector Cable Type
0 - 0.2 f/
0 - 0.5 f/
* 0 - 1 f/
* 0 - 2 f/
* 0 - 5 f/
* 0 - 10 f/
* 0 - 20 f/
* 0 - 30 f/
0 - 50 f/
0 - 100 f/
C 0 - 200 f/
F 0 - 300 f/
H 0 - 350 f/
M -760mmHg - 0 f/
O -760mmHg - 1 f/
Q -760mmHg - 5 f/
V -760mmHg - 10 f/
X -760mmHg - 20 f/
Y -760mmHg - 30 f/
Z Others
P2 PT 1/2"
Process Connection
P8 PT 3/8
F8 PF 3/8" (Standard) In case of ordering
ZZ
Others
only cable, code shall
be‘TPS2I’,‘TPS2L’,
00 None
‘TPS5I’,‘TPS5L’, etc.
2I “I”Type 2M
Option (Connector cable) 2L “L”Type 2M
5I “I”Type 5M
5L “L”Type 5M
Specifications
Measuring
range
-760mmHg ~ 0 to 30 Kg/A (Compound pressure)
0~0.2 to 350 Kg/G (Gauge pressure)
0~1.0 to 30 Kg/Abs (Absolute pressure)
Allowable over pressure
300% of max. Span
Power supply
15V~35VDC
Electric
characteristic
Output
Load resistance
Consumption power
4-20mA DC
600Ω Max
0.5W
±0.3% F.S(Linearity, Hysteresis, Repeatability)
Accuracy
Linearity
±0.3% F.S
-10~50±0.3% F.S
50~70±0.5% F.S((except for -10~50))
Using temp. / Humidity
Temperature
Characteristic
Response time
Connection
Material
Range
Case protection
Weight
Hysteresis
±0.3% F.S
Zero
-10~70, 5~95%RH
±0.03%F.S
Span
±0.03%F.S (25STD.)
Less 100mS
PF 3/8(STD.) (Option : PT 3/8, PT 1/2)
Element
Diaphragm : SUS 316
Sealing : SUS 316
Case
O-ring : Fluorine rubber
Connection : SUS316
Refer to Range table
Weatherproof
Approx. 320g (Head type STD.)
Dimensions
* Above connection is standard type (PF 3/8).
Head Type
DIN Connector Type
59
Connector Cable Type
L type
I type
(Unit : mm)
G-1
PF3/8
Ø30
Ø26.8
PF3/8
Ø22
PF3/8
Ø22
PF3/8



TPS20
TPS20 series
High-Reliability Pressure Transmitter
Connections
• Head Type • DIN Connector Type • Connector Cable Type
5
• External connections
1:
2:
: F.G
5
7
1:
3 : Ground
4:
Recorder
Diagnosis defect
Error situation
It is not outputting.
Output is strangely
fluctuating.
Output value of
zero point is
largely different.
Diagnosis Clause
Does it power on?
Is wiring (+.-) correct?
Is not connection defective?
Is power normally supplied?
Is pressure correctly supplied?
Is there any problem in pressure line?
Is power normally supplied?
Is load resistance of receiving instrument in excess of 600Ω?
How about the transmitting distance to measuring point?
Is the line resistance large? (Max. 600Ω)
TPS20
Terminal
250Ω
24VDC
4-20mA
Power 24VDC load 600Ω
output 4-20mA 2wire
Mounting / Transportation / Storage / Repair
• Mounting : When mounting this unit to pressure line, please use
hexagon of connector instead of pipe wrench.
Also please do not use it where sharp vibration occurs
• Transportation : As precision instrument, because drop or shock
may cause mechanical trouble, please be careful
during transportation.
• Storage : Please store it in the place without moisture, dust, vibration.
• Repair : This unit is unnecessary for repair because detector has
not the operating parts.
Internal parts are usually clean but it shall need repair
according to the using condition.
Regular repair cycle should be done every year. In this case,
please check as following clause.
* Please check external connector damages.
* Please check pressure connector, internal cleanness, corrosion.
* After short circuit, please check isolated resistance between case
and power supply.
* Please check Zero/Span and linearity by using standard pressure
equipment.
G୔ In case of disconnecting sensor in order for repair / checking,
please operate as follows.
GG࿝ Please replace the used O-Ring.
GG࿞ Please be care of sensor diaphragm element in order to avoid
from damages.
High-Reliability Pressure Transmitter
A
Recorders
B
Data
Loggers
C
Indicators
D
Converters
E
Controllers
F
Thyristor
Units
G
Transmitters
H
Temp.
Sensors
I
Thermo
Meters
J
Pressure
Gauges
K
Others
TPS20
Series
IDP
IGP-10 /
IAP-10
KT - 302H
KT - 502H
CN-502H/
CN-501H
SS - 5300
G-2





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)