CAL-DIODE. SKCD08C120I4F Datasheet

SKCD08C120I4F CAL-DIODE. Datasheet pdf. Equivalent

Part SKCD08C120I4F
Description CAL-DIODE
Feature SKCD 08 C 120 I4F Absolute Maximum Ratings Symbol VRRM IF(AV) IFSM Tjmax Conditions Tj = 25 °C, IR .
Manufacture Semikron International
Total Page 2 Pages
Datasheet
Download SKCD08C120I4F Datasheet



SKCD08C120I4F
SKCD 08 C 120 I4F
CAL-DIODE
IF = 8 A
VRRM = 1200 V
Size: 2,85 mm x 2,85 mm
SKCD 08 C 120 I4F
Features
• max. junction 175 °C
• very low forward voltage drop
• positive temperature coefficient
• extreme soft recovery
Typical Applications*
• freewheeling diode for IGBT
Absolute Maximum Ratings
Symbol Conditions
VRRM
IF(AV)
IFSM
Tjmax
Tj = 25 °C, IR = 0.06 mA
Tc = 80 °C, Tj = 175 °C, Fi=PI/2
10 ms
Tj = 25 °C
sin 180°
Tj = 150 °C
Electrical Characteristics
Symbol Conditions
i²t
IR
VF
V(TO)
rT
V(TO)
rT
Tj = 150 °C, sin 180°, 10 ms
Tj = 25 °C, VRRM = 1200 V
Tj = 150 °C, VRRM = 1200 V
Tj = 25 °C, IF = 8 A
Tj = 150 °C, IF = 8 A
Tj = 175 °C, IF = 8 A
Tj = 150 °C
Tj = 150 °C
Tj = 175 °C
Tj = 175 °C
Dynamic Characteristics
Symbol Conditions
trr Tj = 150 °C, 8 A, 600 V, 130 A/µs
Err Tj = 150 °C, 8 A, 600 V, 130 A/µs
Irrm Tj = 150 °C, 8 A, 600 V, 130 A/µs
Thermal Characteristics
Symbol Conditions
Tj
Tstg
Tsolder
Tsolder
Rth(j-c)
10 min.
5 min.
Semitrans Assembly
Mechanical Characteristics
Symbol Conditions
Raster
size
Area total
Anode Metallization
Cathode Metallization
Wire bond
Package
Chips /
Package
Values
1200
6
36
36
175
Unit
V
A
A
A
°C
min. typ. max. Unit
0.30
2.33
2.35
2.19
0.90
181.6
0.82
171.25
6
0.06
0.70
2.65
2.68
2.51
1.10
197.58
0.98
191.22
A²s
mA
mA
V
V
V
V
m
V
m
min. typ. max. Unit
0.92 µs
0.4 mJ
2.6 A
min. typ. max. Unit
-40 175 °C
-40 175 °C
250 °C
320 °C
4.33 K/W
Values
Unit
2,85 x 2,85
8
bondable (Al)
solderable (Ag/Ni)
Al, typ. diameter = 300 µm
wafer frame
1894
mm2
mm²
pcs
SKCD
© by SEMIKRON
Rev. 0 – 16.03.2011
1



SKCD08C120I4F
SKCD 08 C 120 I4F
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.
2
Rev. 0 – 16.03.2011
© by SEMIKRON





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)