VI TELEFILTER
Tfs120.doc
Version 1.2
23.03.2000
VI TELEFILTER
Measurement condition Ambient temperature TA: Input power level: Term...
Description
Tfs120.doc
Version 1.2
23.03.2000
VI TELEFILTER
Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fN: Q-value of matching elements: 23 °C 0 dBm. for input: for output: 30
Filter Specification
TFS 120 - 1/4
460 Ω - 11,2 pF. 440 Ω - 13,0 pF.
( typical value.)
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 120 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 25 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 120 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency Tcf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data Insertion loss (Reference level) : ae Nominal frequency : Centre frequency Pass band : Bandwidth : 1 dB - band width 25 dB - band width Amplitude ripple in pass band (p-p): Relative attenuation arel : fN fc at ambient temperature ( fCAT )
typ. value 12,50 dB
tolerance / limit max 15 120 dB MHz
120,01
MHz fN – 100 kHz ..... fN + 100 kHz
260 764 0,7
kHz MHz dB
min. 200 max. 800 max. 1,0
kHz kHz dB
...