www.DataSheet.co.kr
Features
● ● ● ● ● ● ● ● ●
2:1 Wide Input Voltage Range 20 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield International Safety Standard Approvals UL 1950 Component Recognized Standard 50.8 x40.6x10.2mm Package Efficiency to 86%
POWERLINE
DC/DC-Converter
RP20S_D_TE Series
20 Watt Single, Dual & Triple Output
Selection Guide 12V, 24V and 48V Input Types
Part Number Input Range VDC 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 Output Voltage VDC 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 Output Current mA 4000 4000 1670 1330 4000 4000 1670 1330 4000 4000 1670 1330 ±2000 ±833 ±666 ±2000 ±833 ±666 ±2000 ±833 ±666 Input (4) Current mA 1507 2193 2136 2136 743 1082 1054 1054 367 543 527 527 2193 2136 2136 1082 1054 1041 541 514 508 1926 1959 1885 1919 950 967 931 947 468 477 459 467 Efficiency(5) % 77 80 82 82 78 81 83 83 79 82 83 83 80 82 82 81 83 84 81 85 86 78 78 80 80 79 79 81 81 80 80 82 82 Capacitive(6) Load max. µF 13000 6800 2200 755 13000 6800 2200 755 13000 6800 2200 755 ±3400 ±680 ±450 ±3400 ±680 ±450 ±3400 ±680 ±450 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220 4700 /±220
RP20-123.3SE RP20-1205SE RP20-1212SE RP20-1215SE RP20-243.3SE RP20-2405SE RP20-2412SE RP20-2415SE RP20-483.3SE RP20-4805SE RP20-4812SE RP20-4815SE RP20-1205DE RP20-1212DE RP20-1215DE RP20-2405DE RP20-2412DE RP20-2415DE RP20-4805DE RP20-4812DE RP20-4815DE RP20-123.312TE RP20-123.315TE RP20-120512TE RP20-120515TE RP20-243.312TE RP20-243.315TE RP20-240512TE RP20-240515TE RP20-483.312TE RP20-483.315TE RP20-480512TE RP20-480515TE
3.3 / ±12 3000 / ±300 3.3 / ±15 3000 / ±250 5 / ±12 5 / ±15 2000 / ±300 2000 / ±250
3.3 / ±12 3000 / ±300 3.3 / ±15 3000 / ±250 5 / ±12 5 / ±15 2000 / ±300 2000 / ±250
3.3 / ±12 3000 / ±300 3.3 / ±15 3000 / ±250 5 / ±12 5 / ±15 2000 / ±300 2000 / ±250
Description
The E-Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them ideal for all Telecom and safety applications where approved isolation is required. . They also meet UL 1950 and CSA 950 standards (10) 228 April-2005 www.recom-international.com
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
POWERLINE
DC/DC-Converter
RP20-S_D_TE Series
RP20-4805SEW With Heat Sink
125 100
Derating-Graph (Ambient Temperature)
RP20-4805SE
125 100 75 Output Power (%) 50 25 50 60 70 Ambient Temperature Range (°C) 0 -40 -25 -10 0 80 90 100
Output Power (%)
Natural Convection
75 50 25
Natural Convection
50 60 69 Ambient Temperature Range (°C)
0 -40 -25 -10 0
80 90 100
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at
[email protected]
Typical Characteristics
RP20-4805SE
Efficiency VS Input Voltage 85 84 83 82 81 80 79 78 77 76 75 74 85 84 83 82 81 80 78 76 74 70 65 60
RP20-4805SE
Efficiency VS Output Load
Efficiency (%)
Efficiency (%)
36 40
45
50
55
60
65
70
75
0.5
1
1.5
2
2.5
3
2.5
4
Input Voltage (V)
Output Load (A)
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range 12V nominal input 24V nominal input 48V nominal input 12V Input 24V Input 48V Input 9-18VDC 18-36VDC 36-75VDC Pi Type 36VDC 50VDC 100VDC 25mAp-p DC-DC ON DC-DC OFF Nominal input Single & Dual Triple 3.3V, 5V Auxiliary 20ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 20mA 20W max. ±2% ±2% ±5% ±10% continued on next page www.recom-international.com April-2005 229
Datasheet pdf - http://www.DataSheet4U.net/
Input Filter Input Surge Voltage (100 ms max.)
Input Reflected Ripple (nominal Vin and full load) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see note 7) Remote OFF input current Output Power Output Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
www.DataSheet.co.kr
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Minimum Load (see Note 1) Line Regulation (LL-HL at full load) Single (W) Dual (W) Triple 3.3V, 5V Auxiliary Single Dual Triple 3.3V, 5V Auxiliary Dual Triple 3.3V, 5V Auxiliary Single Dual Triple 3.3V, 5V Auxiliary
RP20-S_D_TE Series
10% of FL ±0.2% ±0.5% ±1% ±5% ±0.5% ±3% ±2% ±5% ±5% ±2% ±5% 75mVp-p 100mVp-p 50mVp-p 1% of Vout ±0.02%/°C, max. 3.3V 5V 12V 15V 500µS 3.9V 6.2V 15V 18V Hiccup, automatic recovery see „Selection Guide“ table 1.600VDC min. 109 Ω min. 300pF max. 300kHz typ. UL 1950, EN60950 -40°C to +85°C(with derating) +100°C Natural convection Natural convection with Heat Sink -55°C to +105°C 10°C/Watt 8.24°C/Watt MIL-STD-810D 10-55Hz, 2G, 30 Min. along X, Y and Z 5% to 95% RH Nickel-Coated copper Non-conductive black.