DatasheetsPDF.com

42LG6000 Dataheets PDF



Part Number 42LG6000
Manufacturers LG
Logo LG
Description (42LG6000 / 42LG6100) LCD TV Service Manual
Datasheet 42LG6000 Datasheet42LG6000 Datasheet (PDF)

www.DataSheet.co.kr Internal Use Only website:http://biz.LGservice.com LCD TV SERVICE MANUAL CHASSIS : LD89F MODEL : 42LG6000 42LG6100 CAUTION 42LG6000-ZA 42LG6100-ZB BEFORE SERVICING THE CHASSIS, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr CONTENTS CONTENTS .... 2 PRODUCT SAFETY ..

  42LG6000   42LG6000


Document
www.DataSheet.co.kr Internal Use Only website:http://biz.LGservice.com LCD TV SERVICE MANUAL CHASSIS : LD89F MODEL : 42LG6000 42LG6100 CAUTION 42LG6000-ZA 42LG6100-ZB BEFORE SERVICING THE CHASSIS, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr CONTENTS CONTENTS .............................................................................................. 2 PRODUCT SAFETY ..................................................................................3 SPECIFICATION ........................................................................................6 ADJUSTMENT INSTRUCTION ...............................................................13 TROUBLE SHOOTING ............................................................................15 BLOCK DIAGRAM...................................................................................22 EXPLODED VIEW .................................................................................. 23 SVC. SHEET ............................................................................................... Copyright C 2008 LG Electronics. Inc. All right reserved. Only for training and service purposes -2- LGE Internal Use Only Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr SAFETY PRECAUTIONS IMPORTANT SAFETY NOTICE Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in the Schematic Diagram and Replacement Parts List. It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent Shock, Fire, or other Hazards. Do not modify the original design without permission of manufacturer. General Guidance An isolation Transformer should always be used during the servicing of a receiver whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect the receiver and it's components from being damaged by accidental shorts of the circuitry that may be inadvertently introduced during the service operation. If any fuse (or Fusible Resistor) in this TV receiver is blown, replace it with the specified. When replacing a high wattage resistor (Oxide Metal Film Resistor, over 1W), keep the resistor 10mm away from PCB. Keep wires away from high voltage or high temperature parts. Leakage Current Hot Check (See below Figure) Plug the AC cord directly into the AC outlet. Do not use a line Isolation Transformer during this check. Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor between a known good earth ground (Water Pipe, Conduit, etc.) and the exposed metallic parts. Measure the AC voltage across the resistor using AC voltmeter with 1000 ohms/volt or more sensitivity. Reverse plug the AC cord into the AC outlet and repeat AC voltage measurements for each exposed metallic part. Any voltage measured must not exceed 0.75 volt RMS which is corresponds to 0.5mA. In case any measurement is out of the limits specified, there is possibility of shock hazard and the set must be checked and repaired before it is returned to the customer. Leakage Current Hot Check circuit AC Volt-meter Before returning the receiver to the customer, always perform an AC leakage current check on the exposed metallic parts of the cabinet, such as antennas, terminals, etc., to be sure the set is safe to operate without damage of electrical shock. Leakage Current Cold Check(Antenna Cold Check) With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to the AC plug prongs tied together and touch other ohm-meter lead in turn to each exposed metallic parts such as antenna terminals, phone jacks, etc. If the exposed metallic part has a return path to the chassis, the measured resistance should be between 1MΩ and 5.2MΩ. When the exposed metal has no return path to the chassis the reading must be infinite. An other abnormality exists that must be corrected before the receiver is returned to the customer. To Instrument's exposed METALLIC PARTS 0.15uF Good Earth Ground such as WATER PIPE, CONDUIT etc. 1.5 Kohm/10W Copyright C 2008 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- LGE Internal Use Only Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr SERVICING PRECAUTIONS CAUTION: Before servicing receivers covered by this service manual and its supplements and addenda, read and follow the SAFETY PRECAUTIONS on page 3 of this publication. NOTE: If unforeseen circumstances create conflict between the following servicing precautions and any of the safety precautions on page 3 of this publication, always follow the safety precautions. Remember: Safety First.


5551 42LG6000 42LG6100


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)