www.DataSheet.co.kr
Pulse Transformers www.schurter.com/pg85 Cost optimized pulse transformers for THT mounting, short ...
www.DataSheet.co.kr
Pulse Transformers www.schurter.com/pg85 Cost optimized pulse transformers for THT mounting, short rise time
ILR
- High insulation rating (>2.2 kVAC) between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics - Cost optimized design - The defined partial discharge voltage guarantees an effecively unlimited serviceable live
Description
Applications
- Galvanic separation of drive- and power-circuit - Mainly used in ignition circuits with Thyristors, Triacs, power
transistors and IGBT's - DC/DC converters - Line coupling transformers in high speed data transmission
References Weblinks
General Product Information Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check
Standards
- VDE 110b
Technical Data
Rated voltage Voltage Time Integral Pulse Rise Time Turns Ratio Terminal technic Weight Material: Housing Sealing Compound up to 500 VAC 150 - 300 Vµs 0.1 - 0.3 µs 1:1, 2:1, 3:1, 1:1:1 THT 7 g Plastics UL 94V-0
Climatic Category Allowable Operation Temp. 25/100/21 acc. to IEC 60068-1 -25 °C to 100 °C
Dimensions Case 05-7
Case 05-8
max. 17.5 12.5 max. 18.5 15
max. 11.5 (0.4) max. 18.5
max. 17.5 5 7.5
max. 11.5 (0.4)
15
Ø0.5
1)
1) Prim.
min. 5
1) Prim.
1)
min. 5
Variants
Turns Ratio 1:1 Tr [μs] 0.2 Iign [A] 1.0 UVAC [V] 500 Uisol [kV] 3.2 Us x Tw [Vμs] 300 Ls [mH] 2.5 RP [Ω] 0.7 RS [Ω] 0.7 CC [...