Document
www.DataSheet.co.kr
General Purpose Relays
SCHRACK
Interface Plug-in Relay XT
I I I I I I I I I
1 pole 16 A, 2 pole 8 A, 1 CO contact or 2 CO contacts DC- or AC coil, sensitive coil 400 mW Reinforced insulation, protection class II (VDE 0700) 4 kV / 8 mm coil-contact Manual test tab, optionally lockable1) Version with mechanical and/or electrical indicator optionally available Suitable for use in Tyco standard RT sockets Recycleable packaging RoHS compliant (Directive 2002/95/EC)
F0289-A
Applications Panel boards, mechanical engineering Approvals
V REG.-Nr. B758, Z E214025 Technical data of approved types on request
Contact data
Contact configuration Contact set Type of interruption Rated current Rated voltage / max.switching voltage AC Maximum breaking capacity AC Limiting making capacity,max 4 s, df 10% Contact material Mechanical endurance DC coil AC coil Rated frequency of operation with / without load Contact Type XT37* XT48* XT48* XT31* XT42* XT42* XT37* XT48* XT48* XT31* XT42* XT42*
1-pole
1 CO
2-pole
2 CO single contact micro disconnection 16 A 8A 240/400 VAC 4000 VA 2000 VA 30 A 15 A AgNi 90/10 > 10 x 106 > 5 x 106 6 / 600 min-1
ratings Load 16 A, 250 VAC, CO contact, 70°C, DF 50%, EN61810-1 8 A, 250 VAC, CO contact, 70°C, DF 50%, DC coils, EN61810-1 8 A, 250 VAC, CO contact, 70°C, DF 50%, AC coils, EN61810-1 16 A, 250 VAC, CO contact, 70°C, DF 50%, EN61810-1 8 A, 250 VAC, CO contact, 70°C, DF 50%, DC coils, EN61810-1 8 A, 250 VAC, CO contact, 70°C, DF 50%, AC coils, EN61810-1 16 A, 250 VAC, CO General Purpose 70°C, DF 50%, UL508 8 A, 250 VAC, CO General Purpose 70°C, DF 50%, DC coils, UL508 8 A, 250 VAC, CO General Purpose 70°C, DF 50%, AC coils, UL508 16 A, 250 VAC, CO General Purpose 70°C, DF 50%, UL508 8 A, 250 VAC, CO General Purpose 70°C, DF 50%, DC coils, UL508 8 A, 250 VAC, CO General Purpose 70°C, DF 50%, AC coils, UL508
Cycles 30x103 50x103 30x103 30x103 50x103 30x103 30x103 30x103 30x103 30x103 30x103 30x103
Coil data
Rated coil voltage range DC coil AC coil Coil power DC coil AC coil Operative range Coil insulation system according UL1446
1)
6...110 VDC 24...230 VAC typ 400 mW typ 0.75 VA 2 class F
Locking function description If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Delivery status is with testing possibility only, to reach locking position please remove the locking plastic pip according drawing.
1
Datasheet Rev. HC1 Issued 2008/03 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change.
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
General Purpose Relays
SCHRACK
I.