Document
www.DataSheet.co.kr
ABC400-10XXG Data Sheet
Features
• • • • • • • • • High efficiency up to 91% at 230VAC Universal AC input voltage range: 90-264 VAC Active power factor correction Over temperature, output overvoltage, overcurrent and short circuit protection Low conducted and radiated EMI (EN 55022 cl A) Safety approval to UL/CSA/EN/IEC60950-1 High power density design: 16 W/in3 Compact size: 3.0 (W) x 1.5 (H) x 5.0 (L) inches ROHS-compliant
Applications
• Telecom, datacom, industrial equipment.
Description
This is a compact and efficient series of AC-DC power supplies suited for telecom, datacom and many other applications. this family meets the international information technology safety standards with the CE-Mark for the European Low Voltage Directive (LVD). their high efficiency allows a very minimal power loss in end equipment, resulting in higher reliability, ease of thermal management and regulatory approvals for an environmentally friendly end product.
Content
1 ORDERING INFORMATION............................................. 2 2 OVERVIEW ....................................................................... 2 3 ABSOLUTE MAXIMUM RATINGS ................................... 3 4 ENVIRONMENTAL AND MECHANICAL ......................... 3 5 INPUT SPECIFICATIONS ................................................ 3 5.1 INPUT FUSE ............................................................ 4 5.2 INRUSH CURRENT ................................................. 4 5.3 INPUT UNDER-VOLTAGE ....................................... 4 5.4 POWER FACTOR CORRECTION ........................... 4 5.5 EFFICIENCY ............................................................ 4 6 OUTPUT SPECIFICATIONS ............................................ 5 7 PROTECTION................................................................... 8
7.1 OVERVOLTAGE PROTECTION ..............................8 7.2 CURRENT LIMITATION ...........................................8 8 POWER GOOD SIGNAL ..................................................9 9 ELECTROMAGNETIC COMPATIBILITY .........................9 9.1 IMMUNITY ................................................................9 9.2 EMISSION ..............................................................10 10 SAFETY / APPROVALS ...............................................10 11 MECHANICAL ..............................................................10 11.1 DIMENSIONS .......................................................11 11.2 CONNECTIONS ...................................................13
Rev. AA, 19-May-2011 PRELIMINARY
Page 1 / 13
www.power-one.com
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
ABC400-10XXG Data Sheet
1 ORDERING INFORMATION
Product Family ABC400-10XX Output Power 400W Dash # Outputs 1 Standard: 0 S-Type: 1-9 0 Vo-Voltage 12VDC / 24VDC / 48VDC RoHS compliant G
2 OVERVIEW
The ABC400-10XXG is a high efficiency and high power density AC to DC power supply. It incorporates interleaved transition mode PFC converter and well proven two-FET forward converter, providing increased system reliability and high efficiency. with around 1m/s system air cooling, ABC400-1012G can delivery up to 360W continuous output power and 408W for ABC400-1024G and ABC400-1048G
Vo
Figure 1: ABC400-10XXG block diagram
Rev. AA, 19-May-2011 PRELIMINARY
Page 2 / 13
www.power-one.com
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
ABC400-10XXG Data Sheet
3 ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and cause permanent damage to the supply. Parameter Conditions / Description Min Nom Max Unit Continuous 264 VAC Vi maxc Max continuous input Transient, 60 ms 300 VAC
4 ENVIRONMENTAL AND MECHANICAL
Parameter Ambient temperature TA Extended temp range TAext Storage temperature TS Dimensions M Weight Conditions / Description Vi min to Vi max, Io nom, ISB nom Derated output Non-operational Width Height Depth Min -10 +50 -40 Nom Max +50 +70 +85 Unit °C °C °C mm mm mm kg
76.2 38.1 127.0 0.5
5 INPUT SPECIFICATIONS
General Condition: TA = -10… 50 °C unless otherwise noted. Active fan air cooling required: 200 LFM (1 m/s) Parameter Vi nom Nominal input voltage Input voltage ranges Vi Max input current Ii max Inrush current limitation Ii p Fi PF Vi on Vi off η Thold
1)
Conditions / Description Normal operating (Vi min to Vi max) Vi nom=115VAC, T= 25°C (see Figure 2) Vi nom=230VAC, T= 25°C (see Figure 3) Vi nom==264VAC, > 0.5 Io nom Ramping up Ramping down Vi nom=230VAC, 0.5∙Io nom, Vo nom, TA = 25 °C Vi nom=230VAC, 1.0∙Io nom, Vo nom, TA = 25 °C After last AC zero point, Vo within regulation, Vi = 115 VAC, Po nom
Min 100 90
Nom
Input frequency Power factor Turn-on input voltage1) Turn-off input voltage1) Efficiency Hold-up Time
47 0.9 80 72
50/60
Max 240 264 6.5 30 60 63 88 80
Unit VAC VAC Arms Ap Hz W/VA VAC VAC % ms
89 90 16
The power supply is.