DatasheetsPDF.com

CNT-35-26 Dataheets PDF



Part Number CNT-35-26
Manufacturers Tyco Electronics
Logo Tyco Electronics
Description Digital Time Delay Relay
Datasheet CNT-35-26 DatasheetCNT-35-26 Datasheet (PDF)

Catalog 1308242 Issued 3-03 P&B CNT series Multifunction, Digital Time Delay Relay/Counter • • • • • • • 10 programmable timing modes + 2 counting modes 0.1 sec. to 9,990 hr. programmable timing range 1 to 99,900 counting range LCD digital display Universal (24-240VAC/VDC) and fixed input types 10A output relay with DPDT contacts Thumbwheel switches for programming File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommen.

  CNT-35-26   CNT-35-26


Document
Catalog 1308242 Issued 3-03 P&B CNT series Multifunction, Digital Time Delay Relay/Counter • • • • • • • 10 programmable timing modes + 2 counting modes 0.1 sec. to 9,990 hr. programmable timing range 1 to 99,900 counting range LCD digital display Universal (24-240VAC/VDC) and fixed input types 10A output relay with DPDT contacts Thumbwheel switches for programming File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing and Counting Modes See the following page for a complete description of all programmable timing and counting modes. Input Data @ 25°C Voltage: Universal Input Type: 24 - 240V ± 15%, 50/60 Hz. AC or DC. Fixed Input Types: 120VAC ± 15%, 50/60 Hz and 12VDC. Power Requirement: Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC. 10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC. Fixed Input Types: 3VA @ 120VAC; 3W @ 12VDC. Transient Protection: Yes. Reverse Voltage Protection: Yes. Timing Specifications Timing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.; 0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr. Timing Adjustment: Digital adjustment via thumbwheel switches. Tolerance: ± 0.5% ± 0.05 sec. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 0.1% ± 0.05 sec. Repeatability (Including first cycle of operation.): ± 0.1% ± 0.05 sec. Reset Time (power interruption): 45 ms, typ.; 60 ms, max. Minimum Pulse Width, Control: 50 ms. Recycle Time: 45 ms, typ.; 60 ms, max. Input Voltages & Limits @ 25°C Input Type Universal Fixed Nominal Voltage 24-240VAC/VDC 120VAC 12VDC Minimum Voltage 20.4VAC/VDC 102VAC 10.2VDC Maximum Voltage 276VAC/VDC 138VAC 13.8VDC Counting Specifications Maximum Count: 1 to 999; 10 to 9,990 (÷10); 100 to 99,900 (÷100). Maximum Count Rate: 100 counts per second. Mimumum Pulse Width:Count (Control): 3 ms.; Reset: 3 ms. Available Counting Functions: Operate at preset count and release at preset count. Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. www.DataSheet.net/ Environmental Data Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Temperature Range: Storage: -20°C to +70°C. Operating: -10°C to +55°C. Humidity: 85% relative humidity, non-condensing. Mechanical Data Termination: 11-pin octal style plug. Enclosure: Beige plastic 1/16 DIN case. Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 4.3 oz. (122g) approximately. External Control: CONTROL, RESET: Active on contact closure or solid state switch closure to RETURN, 0-1.0VDC maximum voltage level (see wiring diagrams for interface circuits. Initial Dielectric Strength Between Open Contacts: 1,000V rms, 60 Hz. Between All Other Conductors: 1,500V rms, 60Hz. Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Universal Input Model Input Voltage 24-240VAC/VDC Part Number CNT-35-96 Accessories Part Number SSA-24C667 Name Mounting Clip Description Ratchet-fit clip slides onto CNT from behind to secure CNT in panel mount applications. SSA-24C668 Protective Cover Clear, flexible cover slips snugly over bezel of CNT to help protect against dust and moisture. Durable cover also helps prevent inadvertant changes of programming switch settings. Fixed Input Models Input Voltage 12VDC 120VAC Part Number CNT-35-26 CNT-35-76 Outline Dimensions 1.88 (47 .8) .32 (8.1) O NC N Wiring Diagrams (Bottom Views) 2.83 (71.9) (pins numbered clockwise from keyway) EXTERNAL CONTROL SWITCHES** CONTROL (COUNT) RETURN 1.76 (44.7) RESET CONTROL RETURN USE SAME FOR RESET RESET 1.88 (47 .8) A 1 1 1 H + .64 (16.3) 1 11 INPUT* _ + 1 11 INPUT* _ Fits 1.77 x 1.77 (45 x 45) Panel cutout 3.15 (80.0) * Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. ** Important: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1211 Refer to inside back cover. Datasheet pdf - http://www.DataSheet4U.co.kr/ Catalog 1308242 Issued 3-03 P&B Protective Cover & Mounting Clip Dimensions SSA-24C668 Protective Cover “A ” 1.99 (50.5) .40 (10.2) SSA-24C667 Mounting C.


CNT-35-96 CNT-35-26 CNT-35-76


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)