Document
RBU1001M
THRU
SINGLE-PHASE GLASS PASSIVATED
RBU1007M
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 10.0 Amperes
FEATURES
* Low leakage * Low forward voltage * Surge overload rating: 200 amperes peak * Mounting position: Any
RBU
MECHANICAL DATA
* UL listed the recognizde component directory file # E252754 * Epoxy: Device has UL flammability classification 94V-O
.880 (22.3) .860 (21.8)
.160 (4.1) .140 (3.5)
.512 (13.0)
.100 (2.54) .085 (2.16)
.080 (2.03) .060 (1.52)
.740 (18.8) .720 (18.3)
.140 (3.56) .130 (3.30)
.085 (2.16) .075 (1.90)
.050 (1.27) .040 (1.02)
.710 (18.0) .690 (17.5)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified. resistive or inductive load.
.210 (5.33) .190 (4.83)
.080 (2.03) .065 (1.65)
.022 (0.56) .018 (0.46)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage
Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TC = *100 oC (Note 4) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method)
SYMBOL VRRM VRMS VDC IO
IFSM
RBU1001M RBU1002M RBU1003M RBU1004M RBU1005M RBU1006M RBU1007M UNITS
50
100
200
400
600
800
1000
Volts
35
70
140
280
420
560
700
Volts
50
100
200
400
600
800
1000
Volts
10.0
Amps
200
Amps
Typical Current Squared Time
I2t
165.9
A2/S
Isolation Voltage of case Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range
VISO Rq JC Rq JA TJ, TSTG
1600 2.3 26 -55 to + 150
VAC 0C/W
0C
ELECTRICAL CHARACTERISTICS(@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL RBU1001M RBU1002M RBU1003M RBU1004M RBU1005M RBU1006M RBU1007M
Maximum Instantaneous Forward Voltage at 5.0A DC
VF
1.1
Maximum DC Reverse Current at Rated DC Blocking Voltage
@TA = 25oC @TA = 100oC
IR
5.0 100
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 3. Equivalent to Vishay's GBU10 Series. 4. "*" Heat Sink Temperature.
5. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
UNITS Volts
uAmps
2010-05 REV:B
RATING AND CHARACTERISTICS CURVES ( RBU1001M THRU RBU1007M )
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
30 20 10 5 TC= 150OC (TYP)
2 1 0.5
TC= 25OC (TYP)
0.2
Pulse test
per one diode
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS
300
sine wave
IFSM
0
8.3ms 8.3ms
200
1 cycle
non-repetitive
Tj=25
100
0 0 12
5
10 20
50 100
NUMBER OF CYCLE
FIG.3 SURGE FORWARD CURRENT CAPABILITY
10
8
6
heatsink Tc
Tc
4
2
sine wave
R-load
on heatsink
0 10 30 50 70 90 110 130 150 170
HEAT SINK TEMPERATURE, (OC)
FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE
THERMAL RESISTANCE (OC/W)
AVERAGE FORWARD CURRENT, (A)
POWER DISSIPATION, (W)
34
30
sine wave TJ = 150 OC
20
10
00
2
4
6
8 10 12 14
AVERAGE RECTIFIED FORWARD CURRENT, (A)
FIG.2 POWER DISSIPATION
4
on glass-epoxi substrate
3
P.C.B
soldering land 5mmf
sine wave
2
R-load
free in air
1
0
0
40
80
120
160
AMBIENT TEMPERATURE, (OC)
FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE
2.4
2.0
with thermal compound
1.6
1.2
0.8
0.4
0
2
3
4
5
6
7
8
MOUNTING TORQUE (kg.cm)
FIG.6 CONTACT THERMAL RESISTANCE fcf
AVERAGE FORWARD CURRENT, (A)
Marking Description
Rectron Logo
RBU100XM
UL Logo
Year – code (Y:Last digit of year&
A:2010, B:2011……)
VYWW
Week – code
(WW:01~52)
Part No. Voltage-code
1-------50V 5-------600V 2-------100V 6-------800V 3-------200V 7-------1000V 4-------400V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE (mm)
CARTON SIZE (mm)
EA PER CARTON
RBU
-B
450
240*239*35
502*251*126
2,700
GROSS WEIGHT(Kg)
13.00
TUBE PACK
PACKAGE
RBU
PACKING CODE -C
EA PER BOX 1,000
INNER BOX SIZE (mm)
490*135*110
CARTON SIZE EA PER CARTON (mm)
510*293*131
2,000
WEIGHT(Kg) 13.62
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications.