DatasheetsPDF.com

S8VK-G48048 Dataheets PDF



Part Number S8VK-G48048
Manufacturers Omron
Logo Omron
Description Switch Mode Power Supply
Datasheet S8VK-G48048 DatasheetS8VK-G48048 Datasheet (PDF)

New Product Switch Mode Power Supply S8VK-G (15/30/60/120/240/480-W Models) Reliable and Easy Operation-Worldwide Power Supply Resistant in tough environments Easy and fast installation The most compact class on the market • Universal input for worldwide applications: 100 to 240 VAC (85 to 264 VAC) • DC input can be available: 90 to 350 VDC • Possible for 2 phases input usage. • Wide operation temperature range: –40 to 70 °C • Power Boost function at 120% • Safety standards: UL508/60950-1, CSA.

  S8VK-G48048   S8VK-G48048


Document
New Product Switch Mode Power Supply S8VK-G (15/30/60/120/240/480-W Models) Reliable and Easy Operation-Worldwide Power Supply Resistant in tough environments Easy and fast installation The most compact class on the market • Universal input for worldwide applications: 100 to 240 VAC (85 to 264 VAC) • DC input can be available: 90 to 350 VDC • Possible for 2 phases input usage. • Wide operation temperature range: –40 to 70 °C • Power Boost function at 120% • Safety standards: UL508/60950-1, CSA C22.2 No. 107.1/60950-1 EN50178 (= VDE0160), EN60950-1 (= VDE0805). Lloyd’s standards, EN60204-1 PELV Safety of Power Transformers: EN61558-2-16 • 15-W,30-W, and 60-W models conform to UL Class 2 output Standards • EMS: EN 61204-3 EMI: EN61204-3 Class B http://www.DataSheet4U.net/ ! Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 17. datasheet pdf - http://www.DataSheet4U.net/ 1 S8VK-G Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. S8VK- @@@@@@ 1 2 3 2. Power Ratings 015: 15 W 030: 30 W 060: 60 W 120: 120 W 240: 240 W 480: 480 W 3. Output voltage 05: 5 V 12: 12 V 24: 24 V 48: 48 V 1. Input voltage types G: Single phase Ordering Information Note: For details on normal stock models, contact your nearest OMRON representative. Power ratings 15 W Input voltage 5V 12 V 24 V 5V 30 W Single phase 100 to 240 VAC 90 to 350 VDC 12 V 24 V 12 V 24 V 24 V 24 V 48 V 24 V 48 V Output Voltage 3A 1.2 A 0.65 A 5A 2.5 A 1.3 A 4.5 A 2.5 A 5A 10 A 5A 20 A 10 A http://www.DataSheet4U.net/ Output current Boost Current 3.6 A 1.44 A 0.78 A 6A 3A 1.56 A 5.4 A 3A 6A 12 A 6A 24 A 12 A Model number S8VK-G01505 S8VK-G01512 S8VK-G01524 S8VK-G03005 S8VK-G03012 S8VK-G03024 S8VK-G06012 S8VK-G06024 S8VK-G12024 S8VK-G24024 S8VK-G24048 S8VK-G48024 S8VK-G48048 60 W 120 W 240 W 480 W 2 datasheet pdf - http://www.DataSheet4U.net/ S8VK-G Specifications Ratings, Characteristics, and Functions Power ratings Item Efficiency (Typical) Voltage *1 Frequency *1 Current (Typical) Power factor (Typical) 115 VAC input 230 VAC input 230 VAC input Output voltage 230 VAC input 77% 50/60 Hz (47 to 450 Hz) 0.32 A 0.2 A 0.42 Conforms to EN61000-3-2 0.14 mA 0.25 mA 16 A 32 A –10% to 15% (with V.ADJ) (guaranteed) 60 mV 50 mV 30 mV 30 mV 30 mV 30 mV 0.5% max. (at 85 to 264 VAC input, 100% load) 3.0% max. (5 V), 2.0% max. (12 V), 1.5% max. (24 V), at 0% to 100% load 0.05%/°C max. 530 ms 330 ms 28 ms 134 ms Yes *5 120% of rated current (Refer to Engineering Data) Yes (Refer to Engineering Data) Possible for up to two Power Supplies (with external diode) –40 to 70°C (Refer to Engineering Data) –40 to 85°C http://www.DataSheet4U.net/ 15 W 5V 12 V 80% 24 V 79% 5V 82% 30 W 12 V 86% 24 V 100 to 240 VAC, 90 to 350 VDC (allowable range: 85 to 264 VAC) *6 0.3 A 0.21 A 0.31 A 0.2 A 0.5 A 0.32 A 0.43 0.57 A 0.37 A 0.42 0.58 A 0.36 A 0.43 Input Harmonic current emissions Leakage current (Typical) Inrush current (Typical) *2 115 VAC input 230 VAC input 115 VAC input 230 VAC input at 20 MHz (Typical) 0.13 mA 0.24 mA Voltage adjustment range *3 Ripple *4 Input variation influence Load variation Influence (Rated Input voltage) Output Temperature variation influence Start up time (Typical) *2 Hold time (Typical) *2 115 VAC input 230 VAC input 115 VAC input 230 VAC input 520 ms 400 ms 29 ms 138 ms 580 ms 400 ms 32 ms 134 ms 550 ms 430 ms 33 ms 177 ms 550 ms 490 ms 36 ms 170 ms 600 ms 480 ms 23 ms 154 ms Overload protection *2 Overvoltage protection *2 Additional Power Boost functions Parallel operation Series operation Ambient operating temperature Storage temperature Ambient operating humidity Dielectric strength (detection current: 20 mA) Insulation resistance Vibration resistance Shock resistance Output indicatior Others EMI EMS Conducted Emission Radiated Emission 121% to 160% of rated load current (130% typ value) 0% to 95% (Storage humidity: 0% to 95%) 3.0 kVAC for 1 min. (between all inputs and outputs) 2.0 kVAC for 1 min. (between all inputs and PE terminal) 1.0 kVAC for 1 min. (between all outputs and PE terminal) 100 M min. (between all outputs and all inputs/ PE terminals) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min. each in X, Y, and Z directions 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions Yes (color: green), lighting from 80% to 90% or more of rated voltage Conforms to EN61204-3 EN55011 Class B and based on FCC Class A Conforms to EN61204-3 EN55011 Class B Conforms to EN61204-3 high severity levels UL Listed: UL508 (Listing, Class2 Output: Per UL1310) UL UR: UL60950-1 (Recognition) cUL: CSA C22.2 No.107.1 (Class2 Output: Per CSA C22.2 No.223) cUR: CSA C22.2 No.60950-1 EN/VDE: EN50178 (=VDE0160), EN60950-1 (=VDE0805) Lloyd’s standards SELV (EN60950-1/EN50178/UL60950-1), PELV (EN60204-1, EN50178), Safety of Power Tr.


S8VK-G48024 S8VK-G48048 S8VK


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)