POWER TVS COMPONENT
05113
30KPA30A
thru
Only One Name Means ProT ek’Tion™
30KPA280A
POWER TVS COMPONENT
APPLICA TIONS ✔ Relay Drives ✔ Mo...
Description
05113
30KPA30A
thru
Only One Name Means ProT ek’Tion™
30KPA280A
POWER TVS COMPONENT
APPLICA TIONS ✔ Relay Drives ✔ Motor (Start/Stop) Back EMF Protection ✔ Module Lightning Protection IEC COMPA TIBILITY (EN61000-4) ✔ 61000-4-5 (Surge): 48A, 8/20µs - L3 (Line-Gnd), L4 (Line-Line) & L1 (Power) FEA TURES ✔ 30,000 Watts Peak Pulse Power per Line (tp=10/1000µs) ✔ Unidirectional & Bidirectional Configurations ✔ Easy Mounting to Printed Circuit Board ✔ Available in Multiple Voltage Types Ranging From: 30V to 280V MECHANICAL CHARACTERISTICS ✔ Molded Case ✔ Weight 5 grams (Approximate) ✔ Flammability rating UL 94V-0 ✔ Marking: Logo, Part Number & Date Code ✔ Positive Terminal Marked with Band - Unidirectional Only AXIAL LEAD
APPLICA TION
TYPICAL RELAY DRIVE PROTECTION VCC
05113.R10 7/05
1
www.protekdevices.com
30KPA30A
thru
30KPA280A
DEVICE CHARACTERISTICS MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER Peak Pulse Power (tp =10/1000µs) - See Fig. 1 Forward Surge Rating (1/20 seconds) - See Note 2 Steady State Power Dissipation Storage Temperature Operating Temperature SYMBOL PPP IF PD TSTG TJ VALUE 30,000 200 1.0 -55 to +150 -55 to +150 UNITS Watts Amps Watts
0 0
C C
ELECTRICAL CHARACTERISTICS
PART NUMBER (Notes 1 & 2) RATED STAND-OFF VOLTAGE BREAKDOWN VOLTAGE MAXIMUM LEAKAGE CURRENT @VWM ID µA 5000 2000 1000 250 20 10 10 10 10 10 10 10 10 10 MAXIMUM CLAMPING VOLTAGE (See Fig. 2) @ 10/1000µs VC @ IPP 55.2V @ 543.0A 61.8V @ 485.0A 73.0V @ 410.0A 77.4V @ 388.0A 92...