Ibex Peak platform cause S3 resume fail issue
ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011 Page: 1
SIO IT8721F-BX/DX in Ibex Peak platform cause S3 resume f...
Description
ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011 Page: 1
SIO IT8721F-BX/DX in Ibex Peak platform cause S3 resume fail issue
Issue Topic:
Technical Issue Survey Form
Prepared by: RD Department:
FISH BUI/ODM1
Doc.: ECS Technical Issue Survey Form V.A
Free Datasheet http://www.datasheet4u.com/
ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011 Page: 2
Document Version History: Reversion V.A Draft Change List Release Date 1/08/2009
Doc.: ECS Technical Issue Survey Form V.A
Free Datasheet http://www.datasheet4u.com/
ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011 Page: 3
1. Technical Issue Survey Priority/Schedule
Priority Target Schedule □ Urgent 2010/1/25 ■ High □ Low
Note: A). Urgent: To finish the survey and solution implementation within one or two days. B). High: To finish the survey and solution implementation within one week. C). Low: To finish the survey within two or three weeks for reference.
2. Technical Issue Description
System will power shutdown when resume from S3 state, refer to below measurement of comparison with the perspective signals PCH circuit core 1.05V and SIO PWROK in failure state:
1)PCH core 1.05V
circuit:
2)SIO PWROK connect to pin 32 PWRGD1_30ms :
Doc.: ECS Technical Issue Survey Form V.A
Free Datasheet http://www.datasheet4u.com/
ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011 Page: 4
3)Below waveform demonstrate fail state of PWROK is ready 28 ms after PCH core 1.05V active:
Below timing diagram of IBX...