KBJ4005 THRU KBJ410
4 Amp GLASS PASSIVATED BRIDGE RECTIFIERS 50 to 1000 Volts
KB J
P A D E B
+
• • • •
Features
Diff used Junc ti on Low Forward Volt age Drop High Curr ent Capabil ity UL Recognized File # E165989
• •
Maximum Ratings
Device Marking
Operating Junction Temperature: -5 5 °C to + 150 °C Storage Temperature: -55°C to +150°C
Catalog Number
K BJ4005 KB J401 KB J 402 KB J404 KB J406 KB J408 KB J410
KBJ4005 KBJ401 KBJ402 KBJ404 KBJ406 KBJ408 KBJ410
Maximum Re current Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V
Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V
Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V
O
F N
~ ~
I
C
G H J L M
K
DIMENSIONS
Electrical Characteristics @ 25 °C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element Maximum DC Reverse Current At Rated DC Blocking Voltage
I t Rating for fusing
2
IF(AV) IFSM VF
4.0A 150A 1.0V
TC = 100°C 8.3ms, half sine IFM = 2.0A per element; TA = 25°C*
IR
10 µA TA = 25°C 500µA TC = 100 °C
93A 2S (t<8.35ms)
DIM A B C D E F G H I J K L M N O P
INCHES MIN MAX .976 .992 .579 .602 .154 .161 .173 .189 .134 .150 .122 .134 .130 .146 .035 .043 .059 .075 .677 .700 .287 .303 .098 .114 .024 .031 .366 .381 .118X45 ° .122 .134
MM MIN MAX 24.80 25.20 14.70 15.30 3.90 4.10 4.40 4.80 3.40 3.80 3.10 3.40 3.30 3.70 0.90 1.10 1.50 1.90 17.20 17.80 7.30 7.70 2.50 2.90 0.60 0.80 9.30 9.70 3.0X45 ° 3.10 3.40
NOTE
It
2
www . cnelectr.com
Free Datasheet http://www.datasheet4u.com/
KBJ4005 THRU KBJ410
Figure 1 Typical Forward Characteristics
100 Figure 2 Typical Reverse Characteristics 1000
100 TJ=25°C 10 10 Amps µ Amps
TJ=125°C
TJ=100°C
1.0 1.0
0.1 TJ=25°C 0.1 0 0.2 0.6 1.0 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 1.4 1.8 .01 0 40 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts 80 120 140
Figure 3 Forward Derating Curve 6 160 5 120 4 80 Amps 2 1 40 Figure 4 Peak Forward Surge Current
Amps
3
Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 25 50 75 °C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 100 125 150
0
1
2
4
6
8 10 Cycles
20
40
60 80 100
0
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
www.cnelectr.com