Document
T-13/4 (5 mm) High Intensity LED Lamps Technical Data
HLMP-331x Series HLMP-341x Series HLMP-351x Series
Features
• High Intensity • Choice of 3 Bright Colors High Efficiency Red Yellow High Performance Green • Popular T-13/4 Diameter Package • Selected Minimum Intensities • Narrow Viewing Angle • General Purpose Leads
• Reliable and Rugged • Available on Tape and Reel
Description
This family of T-13/4 nondiffused LED lamps is specially designed for applications requiring higher on-axis intensity than is achievable with a standard lamp. The light generated is focused to a narrow beam to achieve this effect.
Selection Guide
Luminous Intensity Iv (mcd) @ 10 mA Color Red Part Number HLMP-3315 HLMP-3317 HLMP-3316-I00xx HLMP-3316-IJ0xx HLMP-3415 Yellow HLMP-3416 HLMP-3416-G00xx HLMP-3416-IJ0xx HLMP-3517 Green HLMP-3519 HLMP-3519-F00xx HLMP-3519-IJ0xx Min. 13.8 22.00 22.0 22.0 9.2 14.7 14.7 37.6 6.7 10.6 10.6 43.6 Max. 70.4 120.2 139.6
Free Datasheet http://www.datasheet-pdf.com/
2
Package Dimensions
Part Numbering System
HLMP - 3 x 1 x - x x x xx Mechanical Option 00: Bulk 01: Tape & Reel, Crimped Leads 02: Tape & Reel, Straight Leads B1: Right Angle Housing, Uneven Leads B2: Right Angle Housing, Even Leads Color Bin Options 0: Full Color Bin Distribution Maximum Iv Bin Options 0: Open (no max. limit) Others: Please refer to the Iv Bin Table Minimum Iv Bin Options Please refer to the Iv Bin Table Brightness Level 5, 7: Less Brightness 6, 9: Higher Brightness Color Options 3: GaP HER 4: GaP Yellow 5: GaP Green
Free Datasheet http://www.datasheet-pdf.com/
3
Electrical Characteristics at TA = 25°C
Symbol IV Description Luminous Intensity Device HLMP3315 3316 3415 3416 3517 3519 2θ1/2 Including Angle Between Half Luminous Intensity Points 3315 3316 3415 3416 3517 3519 λPEAK Peak Wavelength 331X 341X 351X 331X 341X 351X 331X 341X 351X 331X 341X 351X 331X 341X 351X 331X 341X 351X 331X 341X 351X All 331X 341X 351X 5.0 145 500 595 Min. 13.8 22 9.2 14.7 6.7 10.6 Typ. 40.0 60.0 40.0 50.0 50.0 70.0 35 35 35 35 24 24 635 583 565 40 36 28 626 585 569 90 90 500 11 15 18 260 Max. Units mcd mcd mcd Deg. Test Conditions IF = 10 mA (Figure 3) IF = 10 mA (Figure 8) IF = 10 mA (Figure 13) IF = 10 mA See Note 1 (Figure 6) IF = 10 mA See Note 1 (Figure 11) IF = 10 mA See Note 1 (Figure 16) Measurement at Peak (Figure 1)
Deg.
Deg.
nm
∆λ1/2
Spectral Line Halfwidth
nm
λd
Dominant Wavelength
nm
See Note 2 (Figure 1)
τs
Speed of Response
ns
C
Capacitance
pF
VF = 0; f = 1 MHz
RθJ-PIN
Thermal Resistance
°C/W
Junction to Cathode Lead IF = 10 mA (Figure 2) IF = 10 mA (Figure 7) IF = 10 mA (Figure 12) IR = 100 µA See Note 3
VF
Forward Voltage
1.9 2.0 2.1
2.4 2.4 2.7
V
VR ηV
Reverse Breakdown Volt. Luminous Efficacy
V lumens Watt
Notes: 1. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity. 2. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelen.