Precision Fixed Attenuator
Precision Fixed Attenuator
50Ω 2W 6dB
-55°C to 100°C** -55°C to 100°C
Coaxial
BW-K6-2W44+
DC to 40 GHz
Features
• DC...
Description
Precision Fixed Attenuator
50Ω 2W 6dB
-55°C to 100°C** -55°C to 100°C
Coaxial
BW-K6-2W44+
DC to 40 GHz
Features
DC to 40 GHz precise attenuation excellent VSWR, 1.20 typ. passivated stainless steel connectors
CASE STYLE: FF1653 Connectors Model Price Qty. 2.9mm Fem - 2.9 Male BW-K6-2W44+ $149.95 ea. (1-24) +RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site for RoHS Compliance methodologies and qualifications
Maximum Ratings
Operating Temperature Storage Temperature
**with mated connectors. Unmated, 85°C max. Permanent damage may occur if any of these limits are exceeded.
Applications Outline Drawing
matching instrumentation test set-ups
Electrical Specifications at 25°C
Parameter Frequency Range Attenuation1
DC - 40 DC - 26.5 26.5 - 37 37 - 40 DC - 18 18 - 26.5 26.5 - 40 DC - 40
Condition (GHz)
Min.
DC — 5.5 5.2 5.2 — — — —
Typ.
— 6 — — — 1.06 1.09 1.50 —
Max.
40 — 6.5 6.8 7.2 1.3 1.4 1.5 2
Unit
GHz
dB
Outline Dimensions ( inch mm )
B .36 9.14 C D .312 .88 7.92 22.35 E wt .312 grams 7.92 4.73
VSWR Input Power2
:1 W
1. At 25°C, accuracy includes frequency and power variations. Temperature coefficient for attenuation: .0004dB/dB/°C typ. 2. Max. power at 25°C ambient, derate linearly to 0.575W at 100°C.
Typical Performance Data
Frequency (GHz) Attenuation (dB)
5.62 5.66 5.72 5.75 5.85 5.92 6.05 6.12 6.08 6.50
VSWR (:1)
1.01 1.01 1.05 1.04 1.10 1.14 1.09 1.12 1.24 1.27
Simplified Electrical Schematic