DatasheetsPDF.com

STANDARD LED. NLSR06S01 Datasheet

DatasheetsPDF.com

STANDARD LED. NLSR06S01 Datasheet






NLSR06S01 LED. Datasheet pdf. Equivalent




NLSR06S01 LED. Datasheet pdf. Equivalent





Part

NLSR06S01

Description

RED STANDARD LED



Feature


NICHIA STS-DA1-1239B NI CHIA CORPORATION SPECIFICATIONS FOR RE D STANDARD LED NLSR06S01 ● LED refer ence standard with temperature control unit for luminous flux and radiant flux calibration http://www.Datasheet4U.co m NICHIA STS-DA1-1239B SPECIFICATIONS (1) Absolute Maximum R atings Item Forward Current Allowable R everse Current Opera.
Manufacture

NICHIA CORPORATION

Datasheet
Download NLSR06S01 Datasheet


NICHIA CORPORATION NLSR06S01

NLSR06S01; ting Temperature Storage Temperature Pla tinum Resistance Temperature Device (RT D) Current Peltier Device Current Pelti er Device Voltage Symbol IF 300 IR 50 T opr Tstg Ipt 2 Ipel Vpel -1 ~ 1 -3.2 ~ 3.2 20 ~ 30 0 ~ 40 Absolute Maximum Rat ing Unit mA mA °C °C mA A V * Absolu te maximum ratings at TA = 25°C. (2) Initial Electrical/Optical Characterist ics Item Forward Volt.


NICHIA CORPORATION NLSR06S01

age Luminous Flux Radiant flux Chromatic ity Coordinate x y Symbol VF Φv Φe Co ndition Tpt = 45°C, IF = 240 mA Tpt = 45°C, IF = 240 mA Tpt = 45°C, IF = 24 0 mA Tpt = 45°C, IF = 240 mA Tpt = 45 C, IF = 240 mA Typ. 2.2 16 105 0.70 0. 30 Unit V lm mW - * Characteristics at TA = 25°C. * The typical values of lu minous flux and radiant flux are tracea ble to the CIE 127:2007-co.


NICHIA CORPORATION NLSR06S01

mpliant national standards. * The chroma ticity coordinates are derived from the CIE 1931 Chromaticity Diagram. * Plati num RTD temperature (Tpt) must be contr olled between 50°C and 60°C. * The LE D incorporated into the socket was char acterized. * The product seasoned for 2 00 hours at TA = 25°C, IF = 240 mA was characterized. (3) Lumen Maintenance * Guaranteed maximum .

Part

NLSR06S01

Description

RED STANDARD LED



Feature


NICHIA STS-DA1-1239B NI CHIA CORPORATION SPECIFICATIONS FOR RE D STANDARD LED NLSR06S01 ● LED refer ence standard with temperature control unit for luminous flux and radiant flux calibration http://www.Datasheet4U.co m NICHIA STS-DA1-1239B SPECIFICATIONS (1) Absolute Maximum R atings Item Forward Current Allowable R everse Current Opera.
Manufacture

NICHIA CORPORATION

Datasheet
Download NLSR06S01 Datasheet




 NLSR06S01
NICHIA STS-DA1-1239B <Cat.No.131111>
NICHIA CORPORATION SPECIFICATIONS FOR RED STANDARD LED
NLSR06S01
LED reference standard with temperature control unit
for luminous flux and radiant flux calibration
http://www.Datasheet4U.com




 NLSR06S01
SPECIFICATIONS
NICHIA STS-DA1-1239B <Cat.No.131111>
(1) Absolute Maximum Ratings
Item
Forward Current
Allowable Reverse Current
Operating Temperature
Storage Temperature
Platinum Resistance
Temperature Device (RTD)
Current
Symbol
IF 300
IR 50
Topr
Tstg
Ipt 2
Peltier Device Current
Peltier Device Voltage
Ipel
Vpel
* Absolute maximum ratings at TA = 25°C.
Absolute Maximum Rating
20 ~ 30
0 ~ 40
-1 ~ 1
-3.2 ~ 3.2
Unit
mA
mA
°C
°C
mA
A
V
(2) Initial Electrical/Optical Characteristics
Item
Symbol
Condition
Typ.
Unit
Forward Voltage
Luminous Flux
Radiant flux
VF
Tpt = 45°C, IF = 240 mA
2.2
V
Φv
Tpt = 45°C, IF = 240 mA
16
lm
Φe
Tpt = 45°C, IF = 240 mA
105
mW
Chromaticity
Coordinate
x
-
Tpt = 45°C, IF = 240 mA
0.70
-
y
-
Tpt = 45°C, IF = 240 mA
0.30
-
* Characteristics at TA = 25°C.
* The typical values of luminous flux and radiant flux are traceable to the CIE 127:2007-compliant national standards.
* The chromaticity coordinates are derived from the CIE 1931 Chromaticity Diagram.
* Platinum RTD temperature (Tpt) must be controlled between 50°C and 60°C.
* The LED incorporated into the socket was characterized.
* The product seasoned for 200 hours at TA = 25°C, IF = 240 mA was characterized.
(3) Lumen Maintenance
* Guaranteed maximum fluctuation of luminous flux is ±3% of the initial value
up to 100 hours of continuous operation at TA = 25°C, Tpt = 45°C (±0.03°C), and IF = 240 mA (±0.1%).
1




 NLSR06S01
DIRECTIONS FOR USE
NICHIA STS-DA1-1239B <Cat.No.131111>
(1) Auxiliary Equipment and System Requirements
The following figure shows how the Luminous Flux Standard LED is connected.
This product
Peltier Controller
Constant Current Power
Supply for LED
Digital Multimeter
for Forward Voltage
Measurements
Recommended specifications for the peripheral equipment
Peltier Controller
Constant Current Power Supply for LED
Digital Multimeter for Forward Voltage Measurements
PID Controller
Temperature measurement accuracy of ±0.03°C.
Drive current accuracy: 0.1% of the set current
Input impedance: 1 G
(2) Installation
The following figure shows how the product should be held by a holder.
(3) Measurement
The product should be measured when luminous flux or radiant flux has stabilized after the start of
temperature control and constant current drive.
Typically, this product will be stable and ready to be used for calibration within 1 to 3 minutes.
Please refer to “STABILITY” on the following page for the characteristics during the first 5 minutes
after the LED starts emission.
2



Recommended third-party NLSR06S01 Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)