Relays. JQX-14FC Datasheet

JQX-14FC Relays. Datasheet pdf. Equivalent

Part JQX-14FC
Description Relays
Feature JQX-14FC1 & JQX-14FC2 (4124)JQX-14FC3 JQX-14FC1 & JQX-14FC2 (4124) JQX-14FC3 03001003501 0600101577.
Manufacture Ningbo
Datasheet
Download JQX-14FC Datasheet

JQX-14FC1 & JQX-14FC2 (4124)JQX-14FC3 JQX-14FC1 & JQX-14FC2 JQX-14FC Datasheet
HHC69A(JQX-14FC) Miniature PCB Relay Model and Description JQX-14FC Datasheet
Recommendation Recommendation Datasheet JQX-14FC Datasheet





JQX-14FC
JQX-14FC1 & JQX-14FC2 (4124)JQX-14FC3
JQX-14FC1 & JQX-14FC2 (4124)
JQX-14FC3
29 12.8 26
03001003501
06001015773
R
C US E160644
R50126370
Features
Heavy load, suitable for heavy power reverse.
Small size, suitable for high-density mounting.
Up to 5000VAC dielectric strength. Between open contacts of JQX-14FC3 3000VAC dielectric strength.
Contact gap of JQX-14FC3 :2 1.5mm=3mm.
Suitable for remote control TV set, copy machine, sales machine and air conditioner etc.
Ordering Information
JQX-14FC1 C S 10 DC12V 0.8 3.5
1
234
5
67
1 Part number JQX-14FC1 JQX-14FC2 JQX-14FC3
2 Contact arrangement A:1A 2A:2A C:1C 2C:2C
3 Enclosure S: Sealed type Z: Dust cover
4 Contact current 3A,5A,6A,8A,10A,16A,20A
5 Coil rated voltage(V) DC:3,5,6,9,12,15,24,48
6 Coil power cunsumption NIL:0.53W 0.8:0.8W 1.2:1.2W
7 Pole-distance 3.5:3.5mm 5:5.0mm
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation life
Electrical
Mechanical
Contact gap
1A SPSTNO 2A DPSTNO 1C SPDT(B-M) 2C DPDT(B-M)
AgCdO AgSnO2
1A:16A/250VAC,30VDC;
1C:10A,16A,20A/250VAC,30VDC;
10A/14VDC(20A Application for 5mm Pole-distance)
2A,2C:5A,8A/220VAC, 30VDC;JQX-14FC3;2A:8A/220VAC;2C:6A/220VAC
Motor load:1HP 250VAC ; 1/2HP 125VAC
Lamp load:TV-5
600W 5000VA
110VDC 380VAC
50m
Max. Switching Current:20A
Item 4.12 of IEC 61810-7
105
107 5 106 (JQX-14FC3)
2 1.5mm=3mm (JQX-14FC3)
Item 4.30 of IEC 61810-7
Item 4.31 of IEC 61810-7
Coil Parameter
Dash
numbers
Coil voltage
VDC
003-530
005-530
006-530
009-530
012-530
024-530
048-530
Rated Max
3 3.9
5 6.5
6 7.8
9 11.7
12 15.6
24 31.2
48 62.4
Coil
resistance
10%
C1C2
Pick up
Release
voltage
voltage
VDC(max) VDC(min)
(75%of rated ( 10%of rated
voltage )
voltage )
Coil power
consumption
W
C1C2
17
47
68
153
275
1100
4350
2.25
3.75
4.50
6.75
9.00
18.0
36.0
0.3
0.5
0.6
0.9
1.2
2.4
4.8
0.53
Operate
Time
ms
C1C2
15
Release
Time
ms
C1C2
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Forward Relay Corporation LTD.
76
http://www.Datasheet4U.com



JQX-14FC
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated Max.
Coil
resistance
10%
C3
Pick up
voltage
VDC(max)
(75%of rated
voltage )
(
Release
voltage
VDC(min)
10%of rated
Coil power
consumption
W
voltage )
C3
2A
Operate
Time
ms
C3
Release
Time
ms
C3
006-670
009-810
012-800
015-830
024-780
6 7.8
9 11.7
12 15.6
15 19.5
24 31.2
54
100
180
270
740
4.50
6.75
9.00
11.3
18.0
0.6
0.9
1.2 0.67W~0.83W
1.5
2.4
2C
10
5
006-900
6 7.8
009-1160 9 11.7
012-1200 12 15.6
015-1250 15 19.5
024-1230 24 31.2
40
70
120
180
470
4.50
6.75
9.00
11.3
18.0
0.6
0.9
1.2 0.9W~1.25W
1.5
2.4
10
5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Creepage distance
Shock resistance
Vibartion resistance
Terminals strength
Relative Humidity
Ambient T emperature
Relative Humidity
Mass
1000M min (at 500VDC)
50Hz 1000V
50Hz 5000V
JQX-14F3C
3000V
4000V Surge voltage 12kV
8mm (only for JQX-14FC3)
100m/s2
11ms
10~50Hz amplitude 1.5mm
10N
235 2 3 0.5s
-40~70 -25~75 (JQX-14FC3)
85% (at 40 )
17g~20g
Item 7 of IEC 60255-5
Item 6 of IEC 60255-5
Item 6 of IEC60255-5
Addenda B of IEC 60255-5
IEC 68-2-2T7est Ea
IEC 68-2-6 T est Fc
IEC 68-2-2e1sTt Ua1
IEC 68-2-20 Test Ta method 1
IEC 68-2-3 Test Ca
Safety approvals
safety approvals
Load
UL&CUR
1C 16A/250VAC
2C 5A/220VAC
1HP 250VAC
1/2HP 125VAC
TV-5
TV
1C 10A/250VAC 14VDC
2C 5A/250VAC 30VDC
CQC
1C:10A/250VAC
77
JQX-14FC1 & JQX-14FC2 (4124)JQX-14FC3
Dimensions
29max.
1.142max.
12.8max.
0.504max.
mm /inch
2-0.4 1
0.016 0.039
2
0.079
2-0.5 1
0.020 0.039
2-0.16 1
0.006 0.039
Dimensions
2-1 0.4
0.039 0.016
4- 1.3
0.051
5- 1.3
0.051
6- 1.3
0.051
8- 1.3
0.051
7.5 7.5
7.5
7.5
0.295
0.295
0.295
0.295
Pole-distance L: 3.5mm or 5mm 0.138 inch or 0.197 inch)
JQX-14FC3:5mm(0.197 inch
Mounting (Bottom view)
(16A)
1A 1C 1A 1C
Wiring diagram
(Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only .
2A 2C
JQX-14FC2 JQX-14FC3
Reference Data
Operate time
20
15
Operate time
10
Release time
5
Coil Power W
Coil temp. Rise
Coil Power W
Life expectancy
1Pole type
2 Pole type
Contact current A
AC Resistive
DC Resistive
Contact voltage V
Ningbo oFrward Relay Corporation LTD.
78





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)