DatasheetsPDF.com

CSLA2DJ Dataheets PDF



Part Number CSLA2DJ
Manufacturers Honeywell
Logo Honeywell
Description Linear Current Sensors
Datasheet CSLA2DJ DatasheetCSLA2DJ Datasheet (PDF)

Solid State Sensors Linear Current Sensors FEATURES ɀ Linear output ɀ AC or DC current sensing ɀ Through-hole design ɀ Fast response time ɀ Output voltage isolation from input ɀ Minimum energy dissipation ɀ Maximum current limited only by conductor size ɀ Adjustable performance and built-in temperature compensation assures reliable operation ɀ Accurate, low cost sensing ɀ Operating temperature range –25 to 85°C ɀ Housing: PET polyester ORDER GUIDE — BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Mt.

  CSLA2DJ   CSLA2DJ


Document
Solid State Sensors Linear Current Sensors FEATURES ɀ Linear output ɀ AC or DC current sensing ɀ Through-hole design ɀ Fast response time ɀ Output voltage isolation from input ɀ Minimum energy dissipation ɀ Maximum current limited only by conductor size ɀ Adjustable performance and built-in temperature compensation assures reliable operation ɀ Accurate, low cost sensing ɀ Operating temperature range –25 to 85°C ɀ Housing: PET polyester ORDER GUIDE — BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Mtg. Dim. Fig. 1 1 2 1 2 1 2 1a 2 1a 1a Supply Volt. (Volts DC) 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 Supply Current (mA Max.) 19 19 19 19 19 19 19 19 19 19 19 Sensed Current (Amps Peak) 57 75 75 100 120 150 225 225 325 325 625 Offset Volt. (Volts±10%) Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Sensitivity mVȿN* At 12 VDC Nominal ± TOL 49.6 39.4 39.1 29.7 24.6 19.6 13.2 13.2 9.1 9.4 5.6 5.8 4.4 4.8 2.7 2.1 1.8 1.2 1.5 1.7 1.3 1.3 Offset Shift (%/°C) ±.05 ±.05 ±.05 ±.05 ±.05 ±.05 ±.05 ±.05 ±.05 ±.05 ±.05 CS Series LINEAR CURRENT SENSORS MICRO SWITCH CS series linear current sensors incorporate our 91SS12-2 and SS94A1 linear output Hall effect transducer (LOHETTM). The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configuration as shown in mounting dimension figures 1, 1a, 2 and 2a. Normal mounting is with 0.375 inch long 4-40 screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors are ratiometric. Catalog Listing CSLA1CD CSLA1CE CSLA1DE CSLA1CF CSLA1DG CSLA1CH CSLA1DJ CSLA1EJ CSLA1DK CSLA1EK CSLA1EL Response Time (µ Sec.) 3 3 3 3 3 3 3 3 3 3 3 BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT Mtg. Dim. Fig. 1 1 2 1 2 2 2 1a 2 1a 1a 1a Supply Volt. (Volts DC) 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 Supply Current (mA Max.) 20 20 20 20 20 20 20 20 20 20 20 20 Sensed Current (Amps Peak) 72 92 92 125 150 225 235 310 400 550 765 950 Offset Volt. (Volts±2%) Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Sensitivity mVȿN* At 8 VDC Nominal ± TOL 32.7 26.1 25.6 19.6 16.2 8.7 9.8 7.6 5.8 4.3 3.1 2.3 3.0 2.1 2.2 1.3 1.1 0.6 1.1 0.7 0.5 0.4 0.3 0.2 Offset Shift (%/°C) ±.02 ±.02 ±.02 ±.02 ±.02 ±.020 ±.0125 ±.0125 ±.0125 ±.0125 ±.007 ±.007 Response Time (µ Sec.) 3 3 3 3 3 3 3 3 3 3 3 3 Catalog Listing CSLA2CD CSLA2CE CSLA2DE CSLA2CF CSLA2DG CSLA2DJ CSLA2DH CSLA2EJ CSLA2DK CSLA2EL CSLA2EM CSLA2EN NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. * N = number of turns PDFINFO p a g e - 0 5 8 http://www.Datasheet4U.com 58 Honeywell Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada CSLW Series Miniature Wired Open-Loop Current Sensors DESCRIPTION Honeywell’s CSLW Series miniature, open-loop current sensors incorporate our SS490 Series miniature ratiometric linear Hall-effect sensor (MRL ). The sensing element is encapsulated in a printed circuit board-mountable plastic package. FEATURES • • • • • • • • • • • • • Wired open-loop design with multiple turns for increased sensitivity ac or dc current sensing Linear ratiometric output Current sinking or sourcing output for interfacing flexibility Low insertion loss Fast response time Compact size for applications with limited space Accurate, low-cost sensing Minimum energy dissipation Maximum current limited only by conductor size Built-in temperature compensation promotes reliable operation Operating temperature range -25 °C to 100 °C [-13 °F to 212 °F] RoHs compliant (lead-free) • • • • • • • • • • • POTENTIAL APPLICATIONS Motor control in appliances, HVAC and consumer tools Current monitoring of electronic circuits Overcurrent protection Ground fault detectors Robotics Industrial process control UPS and telecommunication power supplies Welding current monitoring Battery management systems in mobile equipment Watt meters Variable speed drives TM The combination of sensor, flux collector, housing, and wire coil comprises the current sensor assembly. These sensors are ratiometric. CSLW Series PRODUCT SPECIFICATIONS Product type Package quantity/type Package style Supply voltage Output type Magnetic actuation type miniature hall-effect linear open-loop current sensor 25 per box PC board mount – radial lead IC 4.5 Vdc to 10.5 Vdc sink/source analog ratiometric Parameter Current range (min.) Supply voltage Vout @ 0 AT Supply current typ. max. Turns Coil resistance Sensitivity typ. min. typ. max. Hysteresis Temp error – null max. max. CSLW6B1 ±1 A 4.5 to 10.5 2.50 ±0..


CSLA2DG CSLA2DJ CSLA2DH


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)