DatasheetsPDF.com

Converter Introduction. MC201 Datasheet

DatasheetsPDF.com

Converter Introduction. MC201 Datasheet






MC201 Introduction. Datasheet pdf. Equivalent




MC201 Introduction. Datasheet pdf. Equivalent





Part

MC201

Description

Serial Converter Introduction



Feature


【Introduction】 MC201 is a CAN bus to fiber converter. It designs specially to deal with the short transmission dis tance of CAN bus, the subjection to ele ctromagnetic interference and other iss ues. CAN bus transfer to fiber is able to provide the user with transparent da ta transmission of CAN bus to fiber. It is working in pairs, is more convenien t to put the CAN signa.
Manufacture

3onedata

Datasheet
Download MC201 Datasheet


3onedata MC201

MC201; l revert to the CAN signal through fiber transmission. MC201 serial converter i ntegrates an optical interface and a 2K VAC electrically isolated CAN bus inter face, is able to ◎ Accessories of wa ll-mounted or panel-mounted installatio n If you find that the device is damage d or any parts of it is missing during transportation, please notify the Compa ny or the Company’s .


3onedata MC201

distributor, we will give you proper sol ution as soon as possible. 【Features 】 ◇ Support CAN2.0A and CAN2.0B pro tocol, conform to the ISO/DIS 11898 ◇ Integrate1 UTD CAN interface and 1 opt ical interface ◇ CAN interface suppor ts auto-detect baud rate and user-defin ed baud rate, the baud rate matches the range of 2.5k~1Mbps ◇ Support optic fiber transmit CAN network dat.


3onedata MC201

a ◇ Extend transmission distance to 15 KM ◇ CAN interface has electrical is olation protection with 2KVAC isolation voltage; Supports 8KV ESD protection(a ir discharge) ◇ Port Data Throughput: 1000fps ◇ Optional installation of e xternal termination resistors ◇ Indus trial design, IP40 protection ◇ Suppo rt DIN-Rail and wall mounting MC201 Se rial Converter Introduction r.

Part

MC201

Description

Serial Converter Introduction



Feature


【Introduction】 MC201 is a CAN bus to fiber converter. It designs specially to deal with the short transmission dis tance of CAN bus, the subjection to ele ctromagnetic interference and other iss ues. CAN bus transfer to fiber is able to provide the user with transparent da ta transmission of CAN bus to fiber. It is working in pairs, is more convenien t to put the CAN signa.
Manufacture

3onedata

Datasheet
Download MC201 Datasheet




 MC201
MC201
Serial Converter Introduction
Shenzhen 3onedata Technolgy CO.,Ltd
Address:3/F,2/B,JiuxianglingIndustrialDistrict,NanshanDistrict,
ShenZhen,518055,China
Website :www.3onedata.com.cn
Tel:+86 0755-26702688
Fax:+86 0755-26703485
Introduction
MC201 is a CAN bus to fiber converter. It designs specially to
deal with the short transmission distance of CAN bus, the
subjection to electromagnetic interference and other issues. CAN
bus transfer to fiber is able to provide the user with transparent data
transmission of CAN bus to fiber. It is working in pairs, is more
convenient to put the CAN signal revert to the CAN signal through
fiber transmission.
MC201 serial converter integrates an optical interface and a
2KVAC electrically isolated CAN bus interface, is able to
receive/store/
transmit different rates between 2 CAN network data. CAN bus
interface of MC201 supports various of standard communication
baud rate recommended by CiA, is capable for detecting and
matching automatical baud rate and defining baud rate by user, the
baud rate ranges from 2.5Kbps to 1Mbps; it can connect external
termination resistors at the same time.Its single-model fiber
interface can be used in high-interference environment and has
concentrated energy , which is more suitable for long-distance
transmission , is better to extend the network communication
distance.
MC201 adopts EMC protection design, supports wall and
panel mounting. It can be used at the harsh environment from -40
to
85.
Packing List
The first time use this product, please check the packaging is
intact or not and the attachment is complete or not at first.
3onedata MC201 Serial Converter
(with terminals)x1
User manual x1
Warranty card x1
Certificate x1
Accessories of wall-mounted or
panel-mounted installation
If you find that the device is damaged or any parts of it is
missing during transportation, please notify the Company or the
Company’s distributor, we will give you proper solution as soon as
possible.
Features
Support CAN2.0A and CAN2.0B protocol, conform to the
ISO/DIS 11898
Integrate1 UTD CAN interface and 1 optical
interface
CAN interface supports auto-detect baud
rate and user-defined baud rate, the baud rate
matches the range of 2.5k~1Mbps
Support optic fiber transmit CAN network
data
Extend transmission distance to 15 KM
CAN interface has electrical isolation
protection with 2KVAC isolation voltage;
Supports 8KV ESD protection(air discharge)
Port Data Throughput: 1000fps
Optional installation of external termination
resistors
Industrial design, IP40 protection
Support DIN-Rail and wall mounting
installation
Working Temperature: -40~85
Panel Layout




 MC201
Main view
Top view
Bottom view
1CAN interface5PIN terminals
2DIP switch
3Company name, product line identification
4hangers
5CAN channel status indicator
6Network error status indicator
7Power indicator
8DC-5V Power interface
9Fiber interface
Dimensions
Unitmm
The upper panel of MC201 provides 8 settings of DIP switch
for baud rate matching, I/O1 to ON means the user’s baud rate
setting is valid, otherwise is automatically matched baud rate. 2~6
are status valid values of manually setting baud rate(see table
below), 7, 8 as reservation.
If the set value is not within the scope of the following table,
the baud rate will be set as default 1Mbps. The user changes DIP
switch status are required to re-power.
Power Input
The lower panel of MC201 Serial Converter provides access
port of DC power, wherein the power input is 5VDC. Recommend
to use the power adapter of DC head specification with 2.5mm
inner diameter and 5.5mm outer diameter.
DIP Switch
IO2~IO6 Status RMS
DIP switch up
represent 0, down
indicates 1
111 11
011 11
101 11
110 11
111 01
111 10
001 11
100 11
110 01
111 00
000 11
Identifiable baud rate
(unitbps)
1M
500K
250K
125K
100K
50K
25K
20K
10K
5K
2K5




 MC201
Communication Interface
device is connected with the CAN network via a twisted pair, only
use resistor to short circuit between the twisted pair ports RES+ and
RES- to achieve terminal resistor accession, as shown above.
CAN terminals
CAN Interface:
Pin NO.
1
2
3
4
5
Pin Name
GND
CANL
CANH
RES+
RES-
Pin meaning
Protective Ground
CANL Signal Line
CANH Signal Line
External Terminal Resistor
External Terminal Resistor
MC201 connects with the CAN network via twisted pair.
While MC201 device connects with the CAN network via
twisted pair, CANL connects with CANL, CANH connects with
CANH. According to the ISO11898 standard, to reduce signal
reflections on the CAN bus and enhance the reliability of
communication, terminal matching resistor is usually added to 2
endpoints of the bus. The size of terminal matching resistor is
decided by the characteristic impedance of cable transmission, such
as twisted pair’s characteristic impedance is 120ohm, the 2
endpoints on the bus should be connected 120ohm terminating
resistor. MC201 can set external terminating resistor, when the
Fiber Interface:
Users can select single fiber or dual fiber to transmit optical
signal; when choose single fiber, the optical signal only needs 1
interface through single fiber transmission, the interface is TX/RX;
when choose dual fiber, the transceiver interfaces of optical signals
are separate to TX and RX.
Name
Single Fiber
Interface
TX/RX
Dual Fiber
Interface
TX
RX
Function
Optical signal receive
and send
Optical signal send
Optical signal receive
Since fiber is the point to point connection, MC201’s dual fiber
interface has 2 connectors of TX and RX connect with fiber, the
TX of fiber interface can only connect with the other fiber
interface’s RX through fiber, the specific connection method is
illustrated as below:
MC201 Fiber Interface connection diagram
A MC201 can connect with another MC201 or other device
which has fiber interface via fiber, but it must ensure that the fiber
interface of the device is compatible with the SC fiber interface of
MC201.
Suggestion: Mark labels at the end of the used fibers(as shown
below: A-A, B-B, also can mark A1-A2, B1-B2), for convenient.
LED Indicator
The LED indicator’s monitoring working state of MC201
Serial Converter can fully simplify resolution of fault. Detailed
states of each indicator are shown in the following table:
System Indication LED



Recommended third-party MC201 Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)