ORDER NO. MTNC020203A1 B5 Service Manua l Color Television d e i f i pl m i S Simplified Manual (NA8MS) Panasonic M odels CT-24SX12F CT-24SX12UF CT-27SX12F CT-27SX12UF CT-27SX32F CT-27SX32UF Ch assis BP367 BP367 AP390 AP390 BP390 BP3 90 This simplified service manual is i ssued to add listed models CT-27SX12F/U F and CT-27SX32F/UF to the main service manual order No. .
Manufacture

Panasonic

Datasheet
Download CT-27SX12F Datasheet


Panasonic CT-27SX12F

CT-27SX12F; MTNC010527C1 (CT-27SX31E) and CT-24SX12F /UF models to simplified service manual order number MTNC010837A1 (CT-24SX11E) . A set of unique schematics, unique se ttings and a complete parts list are in cluded in this manual. Please file and use this simplified service manual toge ther with main service manual, order No . MTNC010527C1 (CT-27SX31E) and simplif ied service manual.


Panasonic CT-27SX12F

order number MTNC010837A1 (CT-24SX11E). “WARNING! This Service Manual is de signed for experienced repair technicia ns only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-tec hnical individuals of potential dangers in attempting to service a product. Pr oducts powered by electricity should be serviced or repaire.


Panasonic CT-27SX12F

d only by experienced professional techn icians. Any attempt to service or repai r the product or products dealt with in this Service Manual by anyone else cou ld result in serious injury or death. The service technician is required t o read and follow the “Safety Precaut ions” and “Important Safety Notice in the Main Manual. Copyright 2002 b y Matsushita Electric Corpor.

Part

CT-27SX12F

Description

Color Television Service Manual



Feature


ORDER NO. MTNC020203A1 B5 Service Manua l Color Television d e i f i pl m i S Simplified Manual (NA8MS) Panasonic M odels CT-24SX12F CT-24SX12UF CT-27SX12F CT-27SX12UF CT-27SX32F CT-27SX32UF Ch assis BP367 BP367 AP390 AP390 BP390 BP3 90 This simplified service manual is i ssued to add listed models CT-27SX12F/U F and CT-27SX32F/UF to the main service manual order No. .
Manufacture

Panasonic

Datasheet
Download CT-27SX12F Datasheet




 CT-27SX12F
ORDER NO. MTNC020203A1
B5
Service Manual
Simplified
Color Television
Simplified Manual
(NA8MS)
Panasonic
Models
CT-24SX12F
CT-24SX12UF
CT-27SX12F
CT-27SX12UF
CT-27SX32F
CT-27SX32UF
Chassis
BP367
BP367
AP390
AP390
BP390
BP390
This simplified service manual is issued to add listed models CT-27SX12F/UF and CT-27SX32F/UF to the main
service manual order No. MTNC010527C1 (CT-27SX31E) and CT-24SX12F/UF models to simplified service manual
order number MTNC010837A1 (CT-24SX11E). A set of unique schematics, unique settings and a complete parts list
are included in this manual.
Please file and use this simplified service manual together with main service manual, order No. MTNC010527C1
(CT-27SX31E) and simplified service manual order number MTNC010837A1 (CT-24SX11E).
WARNING! This Service Manual is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the product or products dealt with in this Service Manual by anyone else could result in serious injury or death.”
The service technician is required to read and follow the “Safety Precautions” and “Important Safety Notice” in the Main Manual.
Copyright 2002 by Matsushita Electric Corporation of
America. All rights reserved. Unauthorized copying
® and distribution is a violation of law.




 CT-27SX12F
Important Safety Notice
Special components are used in this television set which are important for safety. These parts are identified on the
schematic diagram by the symbol and printed in BOLD TYPE on the replacement part list. It is essential that
these critical parts are replaced with the manufacturer’s specified replacement part to prevent X-ray radiation,
shock, fire or other hazards. Do not modify the original design without the manufacturer’s permission.
Safety Precautions
General Guidelines
An Isolation Transformer should always be used metallic part has a return path to the chassis, the
during the servicing of a receiver whose chassis is not reading should be between 240kand 5.2MΩ. If the
isolated from AC power line. Use a transformer of exposed metallic part does not have a return path to
adequate power rating as this protects the technician the chassis, the reading should be infinite.
from accidents resulting in personal injury from
electrical shocks. It will also protect the Receiver from
being damaged by accidental shorting that may occur
during servicing.
When servicing, observe the original lead dress,
especially in the high voltage circuit. Replace all
damaged parts (also parts that show signs of
overheating.)
Always Replace Protective Devices, such as
fishpaper, isolation resistors and capacitors, and
shields after servicing the Receiver. Use only
manufacturer’s recommended rating for fuses, circuits
breakers, etc.
High potentials are present when this Receiver is
operating. Operation of the Receiver without the rear
cover introduces danger for electrical shock. Servicing
should not be performed by anyone who is not
thoroughly familiar with the necessary precautions
when servicing high-voltage equipment.
Extreme care should be practiced when Handling the
Picture Tube. Rough handling may cause it to implode
due to atmospheric pressure. (14.7 lbs per sq. in.). Do
Leakage Current Hot Check (Fig. 1)
Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer during the check.
Connect a 1.5k10 watt resistor in parallel with a
0.15µF capacitor between an exposed metallic part
and ground. Use earth ground, for example a
water pipe.
Using a DVM with a 1000 ohms/volt sensitivity or
higher, measure the AC potential across the resistor.
Repeat the procedure and measure the voltage
present with all other exposed metallic parts.
Verify that any potential does not exceed 0.75 volt
RMS. A leakage current tester (such a Simpson Model
229, Sencore Model PR57 or equivalent) may be used
in the above procedure, in which case any current
measure must not exceed 0.5 milliamp. If any
measurement is out of the specified limits, there is a
possibility of a shock hazard and the Receiver must be
repaired and rechecked before it is returned to the
customer.
AC VOLTMETER
not nick or scratch the glass or subject it to any undue
pressure. When handling, use safety goggles and
heavy gloves for protection. Discharge the picture
tube by shorting the anode to chassis ground (not to
COLD
WATER
PIPE
(GROUND)
the cabinet or to other mounting hardware). When
discharging connect cold ground (i.e. dag ground lead)
0.15µF
to the anode with a well insulated wire or use a
grounding probe.
Avoid prolonged exposure at close range to unshielded
areas of the picture tube to prevent exposure to
TO INSTRUMENT’S
EXPOSED METAL
1500,10 W
PARTS
X-ray radiation.
The Test Picture Tube used for servicing the chassis
Figure 1. Hot Check Circuit
at the bench should incorporate safety glass and
magnetic shielding. The safety glass provide shielding
for the tube viewing area against X-ray radiation as
well as implosion. The magnetic shield limits the X-ray
radiation around the bell of the picture tube in addition
to the restricting magnetic effects. When using a
picture tube test jig for service, ensure that the jig is
capable of handling 50kV without causing
X-ray radiation.
Before returning a serviced receiver to the owner,
the service technician must thoroughly test the unit to
ensure that is completely safe to operate. Do not use a
X-ray Radiation
WARNING: The potential source of X-ray radiation in the
TV set is in the High Voltage section and the picture tube.
Note: It is important to use an accurate, calibrated
high voltage meter.
Set the brightness, picture, sharpness and color
controls to Minimum. Measure the High Voltage. The
high voltage should be 30.55 ± 1.25kV. If the upper
limit is out of tolerance, immediate service and
correction is required to insure safe operation and to
prevent the possibility of premature component failure.
line isolation transformer when testing.
Leakage Current Cold Check
Unplug the AC cord and connect a jumper between the
two plug prongs.
Measure the resistance between the jumpered AC plug
and expose metallic parts such as screwheads,
antenna terminals, control shafts, etc. If the exposed
-2-




 CT-27SX12F
About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For
service and repair work, we’d suggest the use of Pb free solder as well, although Pb solder may be
used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol
back of PCB.
stamped on the
Caution
• Pb free solder has a higher melting point than standard solder. Typically the melting
point is 50 ~ 70 °F (30 ~ 40 °C) higher. Please use a high temperature soldering iron
and set it to 700 ± 20 °F (370 ± 10 °C).
• Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the
pins or solder area before applying Pb solder. If this is not practical, be sure to heat the
Pb free solder until it melts, before applying Pb solder.
• After applying PbF solder to double layered boards, please check the component side
for excess solder which may flow onto the opposite side. (see figure below)
remove all of the
excess solder
component
pin
component
slice view
solder
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu
(tin, silver, copper) solder. However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder
can also be used.
0.3mm X 100g
0.6mm X 100g
1.0mm X 100g
-3-



Recommended third-party CT-27SX12F Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)