General Purpose Relays Power Relays Potter & Brumfield T9A Series, DC Coil 30A PCB or Panel Mount Relay n 30A switching in 1 form A (NO) and 20A in 1 form C (CO) sealed case available n Meets UL 508 and 873 spacing - 3.18mm through air, 6.36mm over surface n Option for load connections via 0.250”” (6.35mm) Q.C. terminals n UL class F insulation system standard n Plastic Typical applications HVAC, Appliances, Industrial Controls Approvals UL E58304; CSA LR48471 Technical data of approved t.

  T9AP5D54-24   T9AP5D54-24


Document
General Purpose Relays Power Relays Potter & Brumfield T9A Series, DC Coil 30A PCB or Panel Mount Relay n 30A switching in 1 form A (NO) and 20A in 1 form C (CO) sealed case available n Meets UL 508 and 873 spacing - 3.18mm through air, 6.36mm over surface n Option for load connections via 0.250”” (6.35mm) Q.C. terminals n UL class F insulation system standard n Plastic Typical applications HVAC, Appliances, Industrial Controls Approvals UL E58304; CSA LR48471 Technical data of approved types on request Contact Data Contact arrangement 1 form A (NO), 1 form B (NC), 1 form C (CO) Rated voltage 277VAC Max. switching voltage 277VAC Rated current 30A 15A 20A/10A Limiting continuous current 30A Contact material AgSnOInO, AgCdO Min. recommended contact load 1A, 5VDC or 12VAC Initial contact resistance 75 mΩ at 1A at 5VDC or 12VAC Frequency of operation, with/without load 360/3600hr Operate/release time max., including bounce 15/15ms Contact ratings 1) Type Load Factory AgCdO, 1W coil NO 30A, 240VAC, general purpose NO 25A, 240VAC, resistive CO 20A/10A, 240VAC, general purpose CO 20A/10A, 240VAC, resistive CO 20A/10A, 28VDC, resistive UL 508/873 AgCdO, 1W coil NO 30A, 240VAC, general purpose NC 15A, 240VAC, general purpose CO 20A/10A, 240VAC, general purpose NO 25A, 240VAC, resistive NC 20A, 240VAC, resistive CO 16.75A/13.4A, 240VAC, resistive NO 80LRA/30FLA, 240VAC NC 30LRA/12FLA, 240VAC CO 53.6LRA/20FLA / 20LRA/8FLA, 240VAC NO 98LRA/22FLA, 120VAC NO 2HP, 240VAC NC 1/2HP, 240VAC NO 1HP, 125VAC NC 1/4HP, 125VAC NO 10A, 277VAC, ballast NC 3A, 277VAC, ballast NO 8.3A, 120VAC, tungsten NO 5.4A, 277VAC, tungsten NO 470VA, 120VAC, pilot duty NO 20A, 28VDC, resistive NC 10A, 28VDC, resistive Cycles 100x103 100x103 100x103 100x103 100x103 100x103 100x103 100x103 6x103 6x103 6x103 30x103 30x103 30x103 100x103 1x103 1x103 1x103 1x103 6x103 6x103 6x103 6x103 30x103 100x103 100x103 Contact ratings 1) (continued) Type Load UL 508/873 AgSnOInO, 1W coil NO 30A, 240VAC, general purpose NO 80LRA/30FLA, 240VAC NC 10A, 250VAC, resistive AgCdO, 900mW coil NO 30A, 240VAC, general purpose NO 18A, 240VAC, resistive, 105°C NC 15A, 240VAC, resistive NO 30LRA/15FLA, 240VAC NO 50LRA/16FLA, 120VAC NO 30LRA/11FLA, 120VAC Cycles 100x103 30x103 50x103 100x103 100x103 6x103 100x103 100x103 200x103 1) Contact ratings at 25°C (unless otherwise noteed) with relay properly vented. Remove vent nib after soldering and cleaning. Mechanical endurance 10x106 ops. Coil Data Coil voltage range 5 to 110VDC Max. coil power 110% of nominal Max. coil temperature 155°C Coil insulation system according UL Class F Coil versions, DC coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10% W Code D (1W) coil 5 5 3.75 0.5 25 1 6 6 4.5 0.6 36 1 9 9 6.75 0.9 81 1 12 12 9 1.2 144 1 15 15 11.25 1.5 225 1 18 18 13.5 1.8 324 1 24 24 18 2.4 576 1 48 48 36 4.8 2304 1 110 110 82.5 11 12100 1 Code L (900mW) coil 5 5 3.75 0.5 27 .9 6 6 4.5 0.6 40 .9 9 9 6.75 0.9 97 .9 12 12 9 1.2 155 .9 15 15 11.25 1.5 256 .9 18 18 13.5 1.8 380 .9 24 24 18 2.4 660 .9 48 48 36 4.8 2560 .9 110 110 82.5 11 13450 .9 All figures are given for coil without preenergization, at ambient temperature +23°C. 1) Contact ratings at 25°C (unless otherwise noteed) with relay properly vented. Remove vent nib after soldering and cleaning. 02-2014, Rev. 0214 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Relays Power Relays Potter & Brumfield T9A Series, DC Coil 30A PCB or Panel Mount Relay (Continued) Coil Data (continued) Insulation Data Ambient temperature vs. coil voltage – 1W coil Data below are average values and should be verified in application. Tests were conducted within a 2’ (.6 m) cube (still air); at nominal coil power @ 25°C; with normally open contact loaded; and with 4’ (1.22 m) long, #10 AWG load wires. P.C. board relays were mounted to a 30A, single side P.C. board. Coil rise test conducted with a 30A PC board to maintain 20°C max. rize at 30°C. The relay connections and wiring must be designed with an adequate cross section to ensure proper current flow and heat dissipation. 140 120 Max. Alowable Ambient Temp. (C) 100 80 60 40 20 0 60 Wash-Tight Relay, Vented (2, Load Connections Via Q.C. Terminals, PC Mount Initial dielectric strength between ope.


T9AP5D54-12 T9AP5D54-24 T9AS1D12-5


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)