circuit breaker. A9F74110 Datasheet

A9F74110 breaker. Datasheet pdf. Equivalent

Part A9F74110
Description miniature circuit breaker
Feature Product data sheet Characteristics A9F74110 miniature circuit breaker - iC60N - 1 pole - 10 A - C .
Manufacture Schneider
Datasheet
Download A9F74110 Datasheet



A9F74110
Product data sheet
Characteristics
Complementary
Network frequency
[Ue] rated operational voltage
Magnetic tripping limit
Breaking capacity
[Ics] rated service breaking capacity
Limitation class
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Contact position indicator
Control type
Local signalling
Mounting mode
Mounting support
Nov 4, 2012
A9F74110
miniature circuit breaker - iC60N - 1 pole - 10 A
- C curve
Main
Circuit breaker applica-
tion
Range of product
Device short name
Poles description
Number of protected
poles
[In] rated current
Network type
Trip unit technology
Curve code
Utilisation category
Suitability for isolation
Distribution
IC60
IC60N
1P
1
10 A
AC
DC
Thermal-magnetic
C
Category A EN 60947-2
Category A IEC 60947-2
Yes EN 60898-1
Yes EN 60947-2
Yes IEC 60898-1
Yes IEC 60947-2
50/60 Hz
100...130 V AC 50/60 Hz
12...60 V AC 50/60 Hz
12...72 V DC
220...240 V AC 50/60 Hz
230/400 V AC 50/60 Hz
8 x In +/- 20 %
10 kA Icu EN 60947-2 220...240 V AC 50/60 Hz
10 kA Icu IEC 60947-2 220...240 V AC 50/60 Hz
20 kA Icu EN 60947-2 100...130 V AC 50/60 Hz
20 kA Icu IEC 60947-2 100...130 V AC 50/60 Hz
36 kA Icu EN 60947-2 12...60 V AC 50/60 Hz
36 kA Icu IEC 60947-2 12...60 V AC 50/60 Hz
6 kA Icu EN 60947-2 12...72 V DC
6 kA Icu IEC 60947-2 12...72 V DC
6000 A Icn EN 60898-1 230/400 V AC 50/60 Hz
6000 A Icn IEC 60898-1 230/400 V AC 50/60 Hz
6 kA 100 % EN 60947-2 12...72 V DC
6 kA 100 % IEC 60947-2 12...72 V DC
15 kA 75 % EN 60947-2 100...130 V AC 50/60 Hz
27 kA 75 % EN 60947-2 12...60 V AC 50/60 Hz
7.5 kA 75 % EN 60947-2 220...240 V AC 50/60 Hz
15 kA 75 % IEC 60947-2 100...130 V AC 50/60 Hz
27 kA 75 % IEC 60947-2 12...60 V AC 50/60 Hz
7.5 kA 75 % IEC 60947-2 220...240 V AC 50/60 Hz
3 EN 60898-1
3 IEC 60898-1
500 V AC 50/60 Hz EN 60947-2
500 V AC 50/60 Hz IEC 60947-2
6 kV EN 60947-2
6 kV IEC 60947-2
Yes
Toggle
Trip indicator
Removable comb busbar installed
DIN rail
1



A9F74110
9 mm pitches
Width
Colour
Connections - terminals
Wire stripping length
Tightening torque
Earth-leakage protection
Environment
Standards
IP degree of protection
Pollution degree
Electrical shock protection class
Tropicalisation
Relative humidity
Operating altitude
Ambient air temperature for operation
Ambient air temperature for storage
2
18 mm
White
Tunnel terminal with flap top or bottom 1...25 mm² solid 1
Tunnel terminal with flap top or bottom 0.5...16 mm² flexible with cable end 1
Tunnel terminal with flap top or bottom 0.5...16 mm² flexible without cable end 1
Tunnel terminal with flap top or bottom 1.5 mm² flexible without cable end 1...5
Tunnel terminal with flap top or bottom 1.5 mm² solid 1...5
Tunnel terminal with flap top or bottom 2.5 mm² flexible without cable end 1...3
Tunnel terminal with flap top or bottom 2.5 mm² solid 1...3
14 mm top or bottom
2 nm top or bottom
Separate block
EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
IP3 EN 60947-2
IP3 IEC 60947-2
3 EN 60947-2
3 IEC 60947-2
Class II front face
2 EN/IEC 60068-2-78
95 %
0...2000 m
-35...70 °C
-40...85 °C
2