DatasheetsPDF.com

V163N-20-6.3 Dataheets PDF



Part Number V163N-20-6.3
Manufacturers Trend
Logo Trend
Description INTERNAL THREADED END-CONNECTION LINEAR VALVE PN16
Datasheet V163N-20-6.3 DatasheetV163N-20-6.3 Datasheet (PDF)

INTERNAL THREADED END-CONNECTION LINEAR VALVE PN16 FEATURES • • • • • • V163N PRODUCT DATA Brass body with internal threaded end connections Low seat leakage rate Self-adjusting packing Accurate positioning to ensure state-of-the-art temperature control Directly-coupled electric actuators for easy mounting Constant total flow throughout full plug travel SPECIFICATIONS Action: Nominal pressure rating: Flow characteristic: Rangeability: Leakage rate: Stroke: Valve body: Pipe connections: Mater.

  V163N-20-6.3   V163N-20-6.3



Document
INTERNAL THREADED END-CONNECTION LINEAR VALVE PN16 FEATURES • • • • • • V163N PRODUCT DATA Brass body with internal threaded end connections Low seat leakage rate Self-adjusting packing Accurate positioning to ensure state-of-the-art temperature control Directly-coupled electric actuators for easy mounting Constant total flow throughout full plug travel SPECIFICATIONS Action: Nominal pressure rating: Flow characteristic: Rangeability: Leakage rate: Stroke: Valve body: Pipe connections: Material: Dimensions: Trim: Seat: Plug: Stem: Packing: Stem up to close port A-AB PN16 equal percentage: port A-AB linear: port B-AB 50:1 ≤0.05% of k vs 20 mm Internal threading as per ISO228 Brass See Fig. 1 on page 2 DN15: stainless steel DN20...50: body integrated Brass Stainless steel Spring-loaded carbon fiber reinforced PTFE V-rings 2 to 120 °C max. 1600 kPa 120 to 170 °C max. 1490 kPa APPLICATION • • • Single seated control or shut-off valve for: hot water; chilled water;; domestic hot water; Medium temperature and pressure: Water in heating, ventilation, air conditioning systems, and open circuits. Operated by electric linear actuators (e.g. AL0620 and AL1820) Max. temperature differential in alternating hot/cold 60 K water use: Maximum glycol 50% concentration V163N Data Sheet TA200891 Issue 2 24-Sep-12 1 EN0B-0529GE51 R0905 (EB-V162/3N) V163N Data Sheet SIZES AND FLOW CAPACITIES Table 1. Size and flow capacity (in m /h) Order Number V163N-15-2.5 V163N-15-4.0 V163N-20-6.3 V163N-25-10 V163N-32-16 V163N-40-25 V163N-50-40 Valve size DN15 DN15 DN20 DN25 DN32 DN40 DN50 k VS m /h 2.5 4 6.3 10 16 25 40 3 3 INSTALLATION Water should meet VDI2035 requirements. Do not install valve with stem below the horizontal. Fluid flow must correspond with the arrow direction on the valve body. The installation of a strainer is strongly recommended. CLOSE-OFF PRESSURE RATINGS Electric Actuators actuator type AL0620 AL1820 force 600 N 1800 N DN15 1600 DN20 1600 Table 2. Close-off pressure ratings (in kPa) of electric actuators valve size DN25 DN32 1000 1600 700 1600 DN40 460 1500 DN50 260 850 DIMENSIONS valve size DN15 DN20 DN25 DN32 DN40 DN50 Table 3. Dimensions (in mm) A 83 83 103 106 120 134 B C 65 65 66.5 72.5 77 83.5 Y Y 40 107 B For actuator dimensions, please refer to: C AL0620-24-x, -230-x ...................................... TA200898 AL0620-P-x ..................................................... TA200900 AL1820-24-K, -230-K ...................................... TA200905 AL1820-P-K .................................................... TA200901 A Fig. 1. Dimensions Please send any comments about this or any other Trend technical publication to [email protected] © 2012 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Con.


V163N-15-4.0 V163N-20-6.3 V163N-25-10


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)