SLIM POLARIZED RELAY
TN RELAYS
• Surge voltage withstand: 1500 V FCC Part 68 • Self-clinching terminal also available
14 .551
5.6 .220 9.8 .386
FEATURES
• Small header area makes higher density mounting possible • High sensitivity: 140 mW nominal operating power (single side stable 3-12 V type)
mm inch
SPECIFICATIONS
Contact
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1A) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Rating Max. switching voltage Max. switching current Min. switching capacity ❇1 Single side stable Nominal operating power 1 coil latching 2 coil latching Mechanical (at 180 cpm) 1 A 30 V DC resistive load Electrical (at 20 cpm) 0.5 A 125 V AC resistive load 2 Form C 60 mΩ Gold-clad silver 1 A 30 V DC, 0.5 A 125 V AC 30 W, 62.5 VA 110 V DC,125 V AC 1A 10 µA 10 mV DC 140 mW (3 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC) 100 mW (3 to 12 V DC) 150 mW (24 V DC) 200 mW (3 to 12 V DC) 300 mW (24 V DC) 108 2 × 105 105
Characteristics
Initial insulation resistance*1 Between open contacts Initial Between contact and breakdown coil voltage Between contact sets FCC surge voltage between open contacts Temperature rise*2 (at 20°C) Operate time [Set time]*3 (at 20°C) Release time [Reset time]*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7 Vibration resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Ambient temperature Humidity Max. 3 [Max. 3 Max. 3 [Max. 3 Min. 1,000 MΩ (at 500 V DC) 750 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 V Max. 50°C ms (Approx. 2 ms (Approx. 2 ms (Approx. 1 ms (Approx. 2
ms) ms)] ms) ms)]
Expected life (min. operations) Note:
Min. 490 m/s2 {50G} Min. 980 m/s2 {100G} 176.4 m/s2 {18G}, 10 to 55 Hz at double amplitude of 3 mm 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Approx. 1.5 g .053 oz
❇1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10 µA 1 mV DC – 10 mA 10 V DC])
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 1 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. 4 * Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs. *6 Half-wave pulse of sine wave: 6 ms. *7 Detection time: 10 µs. *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT .
ORDERING I.