Document
New
FFB
120 x 120 x 25.4 MM SERIES
120.0 0.5 (4.724 0.020) 105.0 0.3 (4.134 0.012) 25.4 0.5 (1.000 0.020) 5.0 0.3 (0.197 0.012) 5.0 0.3 (0.197 0.012)
DIMENSIONS DRAWING
105.0 0.3 (4.134 0.012)
120.0 0.5 (4.724 0.020)
LABEL
* Bearing Type Ball Bearings * Material Impeller & Frame : Plastic(UL 94V-0) * Lead Wires : UL 1007 AWG #24 OR Equivalent Red Wire Positive(+) Black Wire Negative(-) * Weight : 205g (7.23 OZ)
Air Pressure
8- 4.5 0.3 (8- 0.177 0.012)
10.0 (0.394) 335.0 10.0 (13.189 0.394)
P & Q CURVE (AT RATED VOLTAGE)
0.60 0.50 0.40 0.30 0.20 0.10 0
(IN H2O) (mm H2O)
MOUNTING PANEL CUTOUT
OUTLET SIDE
117.0 (4.606) 105.0 (4.134)
FFB1212/24/48X
15.0 12.5 10.0 7.5 5.0 2.5 0 0 0 1.0 40.0 2.0 80.0 Air Flow 3.0 4.0 5.0 (M3/MIN)
(CFM)
INLET SIDE
117.0 (4.606) 105.0 (4.134)
EH SH VH HH
117.0 (4.606)
117.0 (4.606)
105.0 (4.134)
105.0 (4.134)
5.
(
4- 4.5 (4- 0.177)
4- 4.5 (4- 0.177)
(
4.
12 4 88 .0 2)
12 8 03 .0 9)
120.0 160.0
UNIT:
mm (INCH)
MODEL PART NO. FFB1212HH FFB1224HH FFB1248HH FFB1212VH FFB1224VH FFB1248VH FFB1212SH FFB1224SH FFB1248SH FFB1212EH FFB1224EH FFB1248EH FUNCTION -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00
Rated Voltage VDC 12 24 48 12 24 48 12 24 48 12 24 48
Operating Voltage Range VDC 7.0 to 13.2 14.0 to 26.4 28.0 to 56.0 7.0 to 13.2 14.0 to 26.4 28.0 to 56.0 7.0 to 13.2 14.0 to 26.4 28.0 to 53.0 7.0 to 13.2 14.0 to 26.4 28.0 to 53.0
Rated Current Amp 0.65 0.28 0.14 0.79 0.37 0.18 1.03 0.52 0.25 1.45 0.63 0.32
Rated Input Power Watt 7.80 6.72 6.72 9.48 8.88 8.64 12.36 12.48 12.00 17.40 15.12 15.36
Speed R.P.M. 3100
Maximum Air Flow M3 /min 3.249 CFM 114.73
Maximum Air Pressure mmH2 O 7.32 IN H2 O 0.288
Noise dB-A 49.7
3400
3.592
126.85
8.29
0.326
51.9
3700
3.969
140.16
10.64
0.419
54.3
4000
4.257
150.33
12.43
0.489
56.4
* Function type is optional. * The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow. * Noise is measured in anechoic chamber in free air, one meter from intake side. * All readings are typical values at rated voltage. * Specifications are subject to change without notice.
42 http://www.deltaww.com
.