DatasheetsPDF.com

PM200CSA060 Dataheets PDF



Part Number PM200CSA060
Manufacturers Mitsubishi
Logo Mitsubishi
Description INTELLIGENT POWER MODULES
Datasheet PM200CSA060 DatasheetPM200CSA060 Datasheet (PDF)

MITSUBISHI INTELLIGENT POWER MODULES PM200CSA060 FLAT-BASE TYPE INSULATED PACKAGE A B AA - DIA. (4 TYP.) H Y AC W W W R Y AC Y Z V 12 3 4 5678 9 11 13 15 17 19 T Q Q 10 12 14 16 18 AE (15 TYP.) F E C B J AB - THD (6 TYP.) 1. V UPC 2. UFO 3. U P 4. V UPI 5. V VPC 6. VFO 7. V P 8. V VPI 9. V WPC 10. WFO 11. W P 12. V WPI 13. V NC 14. V NI 15. NC 16. U N 17. V N 18. W N 19. FO P N W U V W AH AH Z G M D M S Z Z Y 2.54 MM DIA. (2 TYP.) 0.5 MM SQ. PIN (19 TYP.) AF AG X P AD U N L.

  PM200CSA060   PM200CSA060


Document
MITSUBISHI INTELLIGENT POWER MODULES PM200CSA060 FLAT-BASE TYPE INSULATED PACKAGE A B AA - DIA. (4 TYP.) H Y AC W W W R Y AC Y Z V 12 3 4 5678 9 11 13 15 17 19 T Q Q 10 12 14 16 18 AE (15 TYP.) F E C B J AB - THD (6 TYP.) 1. V UPC 2. UFO 3. U P 4. V UPI 5. V VPC 6. VFO 7. V P 8. V VPI 9. V WPC 10. WFO 11. W P 12. V WPI 13. V NC 14. V NI 15. NC 16. U N 17. V N 18. W N 19. FO P N W U V W AH AH Z G M D M S Z Z Y 2.54 MM DIA. (2 TYP.) 0.5 MM SQ. PIN (19 TYP.) AF AG X P AD U N L K V WPC WP W FO V WPI V UPC UP U FO V UPI V VPC VP V FO V VPI V NC WN FO NC VNI VN UN Description: Mitsubishi Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to 20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel diode power devices. Features: ٗ Complete Output Power Circuit ٗ Gate Drive Circuit ٗ Protection Logic – Short Circuit – Over Current – Over Temperature – Under Voltage Millimeters 17.5 16.5 13.2 11.0 10.0 8.0 7.25 6.0 Dia. 5.5 M5 3.22 2.6 2.0 1.8 1.6 0.5 Sep.2000 Type PM Current Rating Amperes 200 VCES Volts (x 10) 60 OUT V CC OUT V CC OUT V CC OUT V CC OUT V CC GND GND GND GND GND GND GND GND GND GND GND GND TEMP SI SI SI SI SI NC N W V U SI OUT V CC P FO FO FO FO FO Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q R Inches 5.31± 0.04 4.74± 0.02 4.33± 0.04 4.27 3.76± 0.02 3.29 2.01 1.602 1.54 1.37 1.33 1.02 Millimeters 135.0± 1.0 120.5± 0.5 110.0± 1.0 10.5 95.5±0.5 83.5 51.0 40.68 39.0 34.7 33.7 26.0 Dimensions S T U V W X Y Z AA AD AC AD AE AF AG AH Inches 0.69 0.65 0.52 0.43 0.39 0.31 0.285 0.24 0.22 Dia. Metric M5 0.128 0.10 0.08 0.07 0.06 0.02 FO IN IN IN IN IN IN Applications: ٗ Inverters ٗ UPS ٗ Motion/Servo Control ٗ Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM200CSA060 is a 600V, 200 Ampere Intelligent Power Module. 0.95 +0.06/-0.0 24.1 +1.5/-0.0 0.84 0.79 0.780 21.3 20.0 19.82 MITSUBISHI INTELLIGENT POWER MODULES PM200CSA060 FLAT-BASE TYPE INSULATED PACKAGE Absolute Maximum Ratings, T j = 25°C unless otherwise specified Symbol Power Device Junction Temperature Storage Temperature Case Operating Temperature Mounting Torque, M5 Mounting Screws Mounting Torque, M5 Main Terminal Screws Module Weight (Typical) Supply Voltage Protected by OC and SC (V D = 13.5 - 16.5V, Inverter Part) Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) Tj Tstg TC — — — VCC(prot.) Viso Ratings -20 to 150 -40 to 125 -20 to 100 1.47 ~ 1.96 1.47 ~ 1.96 920 400 2500 Units °C °C °C N·m N·m Grams Volts Vrms Control Sector Supply Voltage (Applied between VUP1-VUPC , VVP1-VVPC, VWP1-VWPC, VN1-VNC) Input Voltage (Applied between U P-VUPC , VP-VVPC, WP-VWPC, UN · VN · WN-VNC) Fault Output Supply Voltage (Applied between U FO-VUPC, VFO-V VPC, WFO-VWPC , FO-V NC) Fault Output Current (Sink Current of UFO, VFO, WFO and FO Terminal) VD VCIN VFO I FO 20 20 20 20 Volts Volts Volts mA IGBT Inverter Sector Collector-Emitter Voltage (VD = 15V, VCIN = 15V) Collector Current, (TC = 25°C) Peak Collector Current, (TC = 25°C) Supply Voltage (Applied between P - N) Supply Voltage, Surge (Applied between P - N) Collector Dissipation VCES IC I CP VCC VCC(surge) PC 600 200 400 450 500 595 Volts Amperes Amperes Volts Volts Watts Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200CSA060 FLAT-BASE TYPE INSULATED PACKAGE Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Control Sector Over Current Trip Level Inverter Part Short Circuit Trip Level Inverter Part Over Current Delay Time Over Temperature Protection OC SC toff(OC) OT OTr Supply Circuit Under Voltage Protection UV UVr Supply Voltage VD ID Vth(on) Vth(off) fPWM I FO(H) I FO(L) Minimum Fault Output Pulse Width t FO -20° C ≤ T ≤ 125°C, VD = 15V -20° C ≤ T ≤ 125°C, VD = 15V VD = 15V Trip Level Reset Level Trip Level Reset Level Applied between V UP1-VUPC, VVP1-VVPC, VWP1-VWPC, VN1-VNC Circuit Current VD = 15V, VCIN = 15V, VN1 -VNC VD = 15V, VCIN = 15V, VXP1 -VXPC Input ON Threshold Voltage Input OFF Threshold Voltage Applied between UP-VUPC, VP-VVPC, W P-VWPC, UN · VN · WN-V NC 3-φ Sinusoidal VD = 15V, VFO = 15V VD = 15V, VFO = 15V VD = 15V — — 1.2 1.7 40 13 1.5 2.0 55 18 1.8 2.3 mA mA Volts Volts 310 — — 111 — 11.5 — 13.5 400 560 10 118 100 12.0 12.5 15 — — — 125 — 12.5 — 16.5 Amperes Amperes µs °C °C Volts Volts Volts PWM Input Frequency Fault Output Current — — — 1.0 15 — 10 1.8 20 0.01 15 — kHz mA mA ms Sep.2000 MITSUBISHI INTELLIGENT POWER MODULES PM200CSA060 FLAT-BASE TYPE INSULATED PACKAGE Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector Cutoff Current ICES VEC VCE(sat) VCE = VCES, Tj = 25 °C VCE = VCE.


PM200CSD060 PM200CSA060 PM200CS1D060


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)