Current Transducer
Current Transducer HAL 50..600-S
For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation...
Description
Current Transducer HAL 50..600-S
For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation between the primary (high power) circuit and the secondary (electronic) circuit.
IPN = 50 A
Electrical data
Primary nominal r.m.s. current IPN (A) 50 100 200 300 400 500 600 Primary current measuring range IP (A) ± 150 ± 300 ± 600 ± 900 ± 1000 ± 1000 ± 1000 Type
Features
HAL HAL HAL HAL HAL HAL HAL 50-S 100-S 200-S 300-S 400-S 500-S 600-S
· Open loop transducer using Hall
Effect
· Panel mounting - Horizontal or
Vertical
· Insulated plastic case to UL 94-V0.
30000 ±4 >1 >3 ± 15 25 500 3 > 500 A V kW kW V mA V kV MW
ÎP VOUT RL VC IC Vb Vd Ris
Overload capacity (Ampere Turns) Analogue output voltage @ ± IPN Load resistance TA = 0 .. + 70°C TA = - 25 .. + 85°C Supply voltage (± 5 %) Current consumption (max) Rms rated voltage1) Rms voltage for AC isolation test, 50 Hz, 1 mn Isolation resistance @ 500 VDC
Advantages
· Very good linearity · Very good accuracy · Low temperature drift · Wide frequency bandwidth · Very low insertion losses · High immunity to external
interference
Accuracy - Dynamic performance data
X
e
L
Accuracy 2) @ IPN, TA = 25°C, @ ± 15 V Linearity 2) Electrical offset voltage @ IP = 0, TA = 25°C Residual offset voltage @ IP = 0 after an overload of 3 x IPN Thermal drift of offset voltage TA = - 25 .. + 85°C Thermal drift of gain TA = - 25 .. + 85°C Response time @ 90 % of IP di/dt accurately followed Frequency bandwidth (- 3 dB) 3)...
Similar Datasheet