DatasheetsPDF.com

DVI-2560 Dataheets PDF



Part Number DVI-2560
Manufacturers Digital View
Logo Digital View
Description DVI-D INTERFACE CONTROLLER
Datasheet DVI-2560 DatasheetDVI-2560 Datasheet (PDF)

DVI-D INTERFACE CONTROLLER FOR 2560x1600 resolution TFT PANEL Model: DVI-2560 Part number : 41713002X-3 INSTRUCTIONS CONTENTS Page: 2. Introduction, How to Proceed, Usage Note, Disclaimer 2. System design – Diagram of a suggested system 3. Assembly notes – Important information about system elements 5. Connection & Operation – How to use the controller 7. Connectors, pinouts & jumpers – Essential connection information 11. Controller dimensions 12. Application notes 13. Troubleshooting 14 Spe.

  DVI-2560   DVI-2560


Document
DVI-D INTERFACE CONTROLLER FOR 2560x1600 resolution TFT PANEL Model: DVI-2560 Part number : 41713002X-3 INSTRUCTIONS CONTENTS Page: 2. Introduction, How to Proceed, Usage Note, Disclaimer 2. System design – Diagram of a suggested system 3. Assembly notes – Important information about system elements 5. Connection & Operation – How to use the controller 7. Connectors, pinouts & jumpers – Essential connection information 11. Controller dimensions 12. Application notes 13. Troubleshooting 14 Specifications 15 Appendix I – Graphic Mode Support Table 16. Warranty, Caution & Limitation of Liability, Trademarks 17. Contact details It is essential that these instructions are read and understood before connecting or powering up this controller. 1 Introduction Designed for 2560x1600 LCD monitor applications, the DVI-2560 controller provides easy to use interface controller for: ¾ TFT (active matrix) LCDs with TMDS interface of 2560x1600 resolution Panel model support : 1. LG LM300W01-A3 2. Samsung LTB300M1-P01 3. Samsung LTM300M1-P01 DVI-D input signals of WQXGA (2560x1600 60Hz) standard ¾ HOW TO PROCEED ¾ Ensure you have all parts & that they are correct, refer to: • Connection diagram (separate document for each panel) • Connector reference (in following section) • Assembly notes ¾ Check controller switch & jumper settings (errors may damage the panel) ¾ Prepare the PC ¾ Connect the parts ¾ Understand the operation and functions (in following section) IMPORTANT USAGE NOTE This product is for use by system developers and integrators, the manufacturer accepts no liability for damage or injury caused by the use of this product. It is the responsibility of the developer, integrators or other user of this product to: ¾ Ensure that all necessary and appropriate safety measures are taken. ¾ Obtain suitable regulatory approvals as may be required. ¾ Check power settings to all component parts before connection. ¾ Understand the operation and connectivity requirements of this controller. DISCLAIMER There is no implied or expressed warranty regarding this material. SYSTEM DESIGN A typical LCD based display system utilising this controller is likely to comprise the following: Summary: 1. LCD 2560x1600 resolution panel 2. LCD controller card, DVI-2560 3. TMDS cable 4. Panel power and control signal cable 5. Inverter cable 6. Function controls 7. Function controls cable 8. Source detect LED 9. Backlight status LED 10. DVI-D input 11. Power input (24VDC) Digital View offers a range of accessories such as listed above, to make up complete display solution. 2 ASSEMBLY NOTES This controller is designed for monitor and custom display projects using 2560x1600 resolution TFT panels with WQXGA (2560x1600 60Hz) signal input. The following provides some guidelines for installation and preparation of a finished display solution. Preparation: Before proceeding it is important to familiarize yourself with the parts making up the system and the various connectors, mounting holes and general layout of the controller. As much as possible connectors have been labeled. Guides to connectors and mounting holes are shown in the following relevant sections. 1. LCD Panel: This controller is designed for typical TMDS interface TFT panels with panel voltage 18V. Due to the variation between manufacturers of signal timing and other panel characteristics factory setup and confirmation should be obtained before connecting to a panel. (NOTE: Check panel power jumper settings before connection) Controller card: Handle the controller card with care as static charge may damage electronic components. TMDS signal cable : In order to provide a clean signal it is recommended that TMDS signal cables are no longer than 46cm (18 inches). If loose wire cabling is utilized these can be made into a harness with cable ties. Care should be taken when placing the cables to avoid signal interference. Additionally it may be necessary in some systems to add ferrite cores to the cables to minimize signal noise. Panel power and control signal cable : This cable provides panel power and control signal for the panel. If loose wire cabling is utilized these can be made into a harness with cable ties. Care should be taken when placing the cables to avoid signal interference. Additionally it may be necessary in some systems to add ferrite cores to the cables to minimize signal noise. Inverter Cables: Different inverter models require different cables and different pin assignment. Make sure correct cable pin out to match the inverter. Using wrong cable pin out may damage the inverter. Function Controls: The following section discusses the controls required and the section on connectors provides the detail. The controls are minimal: On/Off, Backlight Brightness (depends on inverter). Function controls cable: The cables to the function switches should be of suitable quality and length so that impedance does not affect performance. Generally lengths up to 1 metre (3 feet) s.


NCB310E2 DVI-2560 SG3225EAN


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)