Current Transducer
Current Transducers HAS 50..600-P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic iso...
Description
Current Transducers HAS 50..600-P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
= 50..600 A
VOUT = ±4 V
Electrical data
Primary nominal r.m.s. current IPN (A) 50 100 200 300 400 500 600 Primary current measuring range IP (A) ±150 ±300 ±600 ±900 ±900 ±900 ±900 Type
HAS HAS HAS HAS HAS HAS HAS
50-P 100-P 200-P 300-P 400-P 500-P 600-P
Features
Hall effect measuring principle Galvanic isolation between primary Isolation voltage 3000 V~ Low power consumption Extended measuring range (3 x IPN) Insulated plastic case made of
polycarbonate PBT recognized according to UL 94-V0 Right angle pins for direct PCB mounting and secondary circuit
VC IC IOC Vd Vb RIS VOUT ROUT RL
Supply voltage (± 5 %) Current consumption Overload capacity R.m.s. voltage for AC isolation test, 60 Hz, 1 mn R.m.s. rated voltage, safe separation Isolation resistance @ 500 VDC Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance approx. Load resistance
±15 ±15 30,000 3 5001) > 1000 ±4V ±40 100 >1
V mA At kV V MΩ mV Ω kΩ
Advantages Accuracy - Dynamic performance data
X Accuracy @ IPN, TA = 25°C (without offset) Linearity 2) (0 .. ± IPN) Electrical offset voltage, TA = 25°C Hysteresis offset voltage @ IPN→ 0 Thermal drift of VOE HAS 50-P
HAS 100..600-P
ε
L
VOE VOH VOT TCε G tr di/dt f
Thermal drift of the gain (% of reading) Resp...