Hall Effect Current Sensors
Hall Effect Current Sensors S22P Series
Features:
• • • • • • Closed Loop type Voltage output Unipolar power supply Conf...
Description
Hall Effect Current Sensors S22P Series
Features:
Closed Loop type Voltage output Unipolar power supply Configurable integrated primary Printed circuit board mounting UL recognised - plastic case material UL94V0
Advantages:
Excellent accuracy and linearity Low temperature drift Wide frequency bandwidth No insertion loss High Immunity to external interferences Optimised response time Current overload capability
TA=25ºC, VCC=+5V, RL=10kΩ
Specifications
Parameters Rated Current Saturation Current Output Voltage Offset Voltage @ If=0 Output Voltage Accuracy Output Linearity Supply Voltage Consumption Current Response Time1 Output Temperature Characteristic Offset Temperature Characteristic Hysteresis allowance Insulation Withstanding Insulation Resistance Frequency Bandwidth Operating Temperature Storage Temperature
1
Symbol If Ifmax VOUT VOE X
S22P006S05 6A ±18A
S22P015S05 15A ±45A VOE ±0.625V @ If
S22P025S05 25A ±75A
2.5V±50mV
2.5V±20mV 0.625V±10mV @ If ±0.2% @ If +5V±5% Typ. 12.5mA @ If=0 ≤ 1.0µs @ di/dt = If / µs < ±0.05mV/ºC
2.5V±15mV
εL
VCC ICC tr TCVOUT TCVOE VOH Vd RIS f TA TS -10ºC~25ºC : ±1.6mV/ºC 25ºC~85ºC : ±0.8mV/ºC
-10ºC~25ºC : ±0.6mV/ºC 25ºC~85ºC : ±0.3mV/ºC ≤0.5mV (0A ⇔ If)
-10ºC~25ºC : ±0.4mV/ºC 25ºC~85ºC : ±0.2mV/ºC
AC 3kV for 1minute (Sensing current 0.5mA) Primary ⇔ Secondary > 500MΩ (@ DC500V) Primary ⇔ Secondary DC … 200 kHz -40ºC~+85ºC -40ºC~+90ºC
Time between 10% input current full scale and 90% of sensor output full...
Similar Datasheet