Document
Standard type:
VDE (AQV258) Reinforced type:
VDE
(AQV253H, AQV254H) (AQV256H)
DIP6-pin type with low on-resistance and reinforced insulation
HE 1 Form A
(AQV25❍, AQV25❍H)
8.8 .346
6.4 .252
3.9 .154
Height includes standoff
1 2 3
8.8 .346
6.4 .252
3.6 .142
mm inch
6
5
4
FEATURES
1. Wide variation of 40V, 60V, 100V, 200V, 250V, 400V, 600V, 1,000V and 1,500V load voltage 2. Low on-resistance of typ. 0.6Ω (AQV251) 3. Reinforced insulation type of 5,000V I/O isolation available
TYPICAL APPLICATIONS
• Measuring instruments • Data communication equipment • Telephone equipment • Automatic meter reading device
RoHS compliant
TYPES
I/O isolation
Output rating*
Load voltage
Load current
Package
Through hole terminal Tube packing style
Part No. Surface-mount terminal
Tape and reel packing style Picked from the Picked from the 1/2/3-pin side 4/5/6-pin side
Packing quantity
Tube
Tape and reel
40 V 500 mA
AQV251
AQV251A
AQV251AX
AQV251AZ
60 V 400 mA
AQV252
AQV252A
AQV252AX
AQV252AZ
100 V 350 mA
AQV255
AQV255A
AQV255AX
AQV255AZ
AC/DC dual use
1,500V
200 V 250 V 400 V 1,000 V 1,500 V
250 mA 200 mA 150 mA 30 mA 20 mA
DIP6-pin
AQV257 AQV253 AQV254 AQV259 AQV258
AQV257A AQV253A AQV254A AQV259A AQV258A
AQV257AX AQV253AX AQV254AX AQV259AX AQV258AX
AQV257AZ AQV253AZ AQV254AZ AQV259AZ AQV258AZ
1 tube contains: 50 pcs.
1 batch contains: 500 pcs.
1,000 pcs.
Reinforced 5,000V
250 V 400 V 600 V
200 mA 150 mA 130 mA
AQV253H AQV254H AQV256H
AQV253HA AQV254HA AQV256HA
AQV253HAX AQV254HAX AQV256HAX
AQV253HAZ AQV254HAZ AQV256HAZ
*Indicate the peak AC and DC values. Note: The surface mount terminal indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Item
Symbol
Type of connection
AQV251(A) AQV252(A) AQV255(A) AQV257(A) AQV253(A) AQV254(A) AQV259(A) AQV258(A) AQV253H(A) AQV254H(A) AQV256H(A)
Remarks
Input
LED forward current LED reverse voltage
Peak forward current
IF VR
IFP
50 mA 5V
1A
f = 100 Hz, Duty factor +0.1%
Power dissipation
Load voltage (peak AC)
Pin VL
75 mW 40V 60V 100V 200V 250V 400V 1,000V 1,500V 250V 400V 600V
Output
Continuous load current
A 0.5A 0.4A 0.35A 0.25A 0.2A 0.15A 0.03A 0.02A 0.2A 0.15A 0.13A A connection: IL B 0.7A 0.6A 0.45A 0.35A 0.3A 0.18A 0.04A 0.025A 0.3A 0.18A 0.14A Peak AC, DC
C 1.0A 0.8A 0.70A 0.5A 0.4A 0.25A 0.05A 0.04A 0.4A 0.25A 0.16A B, C connection: DC
Peak load current
Power dissipation Total power dissipation I/O isolation voltage
Temperature Operating
limits
Storage
Ipeak
Pout PT Viso
Topr
Tstg
1.8A
1.5A
1.0A
0.75A 0.6A 0.5A 0.09A 0.06A
1,500 V AC
360 mW 410 mW
–40°C to +85°C –40°F to +185°F
–40°C to +100°C –40°F to +212°F
0.6A
0.5A
0.4A
A connection: 100 ms (1 shot) VL = DC
5,000 V AC
Non-condensing at low temperatures
–1–
ASCTB143E 201406-T
HE 1 Form A (AQV25❍, AQV25❍H)
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
Item
Symbol
Type of con- AQV251(A) AQV252(A) AQV255(A) AQV257(A) AQV253(A) AQV254(A) AQV259(A) AQV258(A) AQV253H(A) AQV254H(A) AQV256H(A)
nection
Condition
LED operate current
Typical IFon
Maximum
—
0.9 mA
3 mA
1.4 mA
IL = Max.
Input
LED turn off current
Minimum Typical
IFoff
—
0.8 mA
0.4 mA
1.3 mA
IL = Max.
LED dropout voltage
Typical Maximum
VF
—
1.25 V (1.14 V at IF = 5 mA) 1.5 V
IF = 50 mA
Typical Maximum
Ron
A
0.6 Ω 0.74 Ω 1.8 Ω 1 Ω 1.4 Ω 2.5 Ω
2.6 Ω 4Ω
5.5 Ω 12.4 Ω 85 Ω 345 Ω 8 Ω 16 Ω 200 Ω 500 Ω
5.5 Ω 12.4 Ω 8 Ω 16 Ω
20 Ω 30 Ω
IF = 5 mA IL = Max. Within 1 s on time
Output
On resistance
Typical Maximum
Ron
B
0.3Ω 0.37 Ω 0.9 Ω 1.4 Ω 0.5 Ω 0.7 Ω 1.25 Ω 2 Ω
2.7 Ω 4Ω
6.2 Ω 60 Ω 345 Ω 2.7 Ω 8 Ω 100 Ω 500 Ω 4 Ω
6.2 Ω 8Ω
15 Ω 20 Ω
IF = 5 mA IL = Max. Within 1 s on time
Typical Maximum
Ron
0.15 Ω 0.18 Ω 0.45 Ω 0.7 Ω 1.4 Ω 3.1 Ω 30 Ω 160 Ω 1.4 Ω 3.1 Ω 7.5 Ω IF = 5 mA
C 0.25 Ω 0.35 Ω 0.63 Ω 1 Ω
2Ω
4 Ω 50 Ω 250 Ω 2 Ω
IL = Max.
4Ω
10 Ω
Within 1 s on time
Off state leakage current
Turn on time*
Maximum ILeak Typical
Ton Maximum
— 1 μA
1.7 ms 1.4 ms 0.9 ms 1.5 ms
—
3 ms
2 ms 3 ms
0.8 ms 2 ms
10 μA
0.6 ms 0.35 ms 1 ms
2.4 ms 4 ms
1 μA
1.8 ms 1.2 ms 3ms
IF = 0 mA VL = Max.
IF = 5 mA IL = Max.
Transfer characteristics
Turn off time*
Typical Toff
Maximum
—
0.07 ms
0.09 ms 0.1 ms 0.06 ms 0.05 ms 0.2 ms
0.04 ms
0.06 ms 0.05 ms 0.06 ms IF = 5 mA IL = Max.
I/O capacitance
Typical Ciso
Maximum
—
1.3 pF 3 pF
f = 1 MHz VB = 0 V
Initial I/O isolation resistance
Minimum Riso
—
1,000 MΩ
500 V DC
*Turn on/Turn off time
Input
Output Ton
90% 10% Toff
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
Item
Symbol
Recommended value
Input LED current
IF
Standard type: 5 Reinforced insulation type: 5 to 10
Unit mA