Triggered Vacuum Gaps
Triggered Vacuum Gaps
EVERYTHING IN A NEW LIGHT.
T
he Triggered Vacuum
GPV-Series
Spark Gaps are ideal high-voltage...
Description
Triggered Vacuum Gaps
EVERYTHING IN A NEW LIGHT.
T
he Triggered Vacuum
GPV-Series
Spark Gaps are ideal high-voltage switches for applications where a wide operating voltage range is desired. The low end of the operating voltage range is independent of the Static Breakdown Voltage (SBV). Operating ranges from 300 volts to 80 kilovolts are possible. Switching times (from the trigger input to the start of main gap current flow) of less than 1 microsecond may be achieved when using a suitable trigger. These switches are commonly used in “crowbar” circuits for protection against overvoltage conditions.
Features Wide operating voltage range Ceramic-metal construction No warm up period High current capability Long life
Standard Model Operating Characteristics
Static Breakdown Voltage (2,7) (Kilovolts) 65 50 100 65 40
(1)
Type Number GPV-63 GPV-6301 GPV-6313 GPV-6322 GPV-7013
Maximum Peak Current (3) (Kiloamperes) 50 50 60 60 20
Maximum Conducted Charge per shot (4) (Coulombs) 0.5 0.5 0.5 0.5 0.3
Contains Wall Shield (5) (Y/N) N N Y Y N
Contains Mercury (6) (Y/N) Y Y N N N
Typical Operating Voltage Range (Kilovolts) 0.3 - 50 0.3 - 40 0.3 - 80 0.3 - 50 0.3 - 32
Environmental Specifications
Ambient temperature range Operating temperature range Nonoperating temperature range Vibration Shock Thermal Shock -54 to +100°C without mercury, -54 to +50°C with mercury -65 to +125°C 15 to 500 Hz at 10 g maximum 50 g, 11 milliseconds -65 to +125°C
Electrical Specificatio...