Euro Standard Isolation Transformer
TT1202-TT1211
KVA: Input Voltage: Output Voltage: Taps: Insulation Class:
15 - 750 575 Delta 415/400/380 Wye ± 5% FC (See Wiring Diagram) 220º C
Phase: Frequency: BIL: Coils: Temp Rise:
Three-Phase 50/60Hz 10 kV Copper 150º C
NEMA 3R Outdoor Enclosure
Full 10 Year Warranty
European Output Voltages
TEMCo Euro-Standard transformers are used to converter standard 3 phase U.S. voltages to standard 3 phase European voltages. This is useful when importing European Machinery into the U.S. Additionally, these transformers are rated for either 50Hz or 60Hz, allowing them be connected in reverse to convert European voltages to U.S. voltages when importing U.S. machinery into Europe. Either way, these transformers are built to last, guaranteed! That’s why we back these with a decade long warranty.
Don’t have floor space to mount your TEMCo EuroStandard transformer? No problem! Heavy duty wall mounting brackets are supplied on all Euro-Standard transformers up to 45KVA. For larger units, take advantage of the weather shields included with every unit and mount your Euro-Standard transformer outside. Save your valuable floor space for your machinery instead of cluttering it with electrical equipment.
Connections are made simple with TEMCo EuroStandard transformers. Multiple taps are provided on the output for 380, 400, or 415v Wye configured outputs. All your input and output connections can be made via the provided fast connection lugs. Rigid GPO-3 fiberglass primary buss strut ensures connections remain secure through the life of the installation.
Corporate Headquarters:
TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538
Inside USA (800) 613-2290 International (510) 490-2187 Fax (510) 490-1507
www.temcotransformer.com
Euro Standard Isolation Transformer
TT1202-TT1211
TT1202 TT1203 TT1204 TT1205 TT1206 TT1207 TT1208 TT1209 TT1210 TT1211
Impedance:
15 kVA
4.5 %
30 kVA
4.5 %
45 kVA
5.0 %
75 kVA
4.0 %
112.5 kVA 4.5 %
150 kVA 4.5 % - 5.5 %
225 kVA 5.0 % - 6.0 %
300 kVA 5.0 % - 6.0 %
500 kVA 4.5 % - 5.5 %
750 kVA 5.0 % - 7.0 %
Wiring Connection Primary: 575v H1-H2-H3
Secondary: Voltage 415 400 380
X1-X2-X3-X4-X5-X6-X7-X8-X9 Connect Load To X7-X8-X9 X4-X5-X6 X1-X2-X3
Corporate Headquarters:
TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538
Inside USA (800) 613-2290 International (510) 490-2187 Fax (510) 490-1507
www.temcotransformer.com
Euro Standard Isolation Transformer
D E
TT1202-TT1211
K L
M
C H
FG
I J B
N
O A
Approximate dimensions given in inches
A B C D E F G H I J K L M N O lbs 15 kVA 13 1/2 19 1/4 21 18 15 3/4 8 11 1/2 1/2 1/2 18 20 3/4 16 1 1/2 1 3/8 7 1/2 180 30 kVA 18 1/2 23 3/4 26 1/4 22 5/8 20 1/2 8 11 1/2 1/2 1/2 22 5/8 26 1/4 20 3/4 1 1/2 1 3/8 10 290 45 kVA 18 1/2 23 3/4 26 1/4 22 5/8 20 1/2 8 11 1/2 1/2 1/2 22 5/8 26 1/4 20 3/4 1 1/2 1 3/8 10 330 75 kVA 19 1/4 27 1/2 31 1/2 26 1/2 24 1/2 8 11 1/2 1/2 1/2 26 1/2 29 1/4 21 3/4 1 1/2 1 3/8 11 1/2 520
Corporate Headquarters:
TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538
Inside USA (800) 613-2290 International (510) 490-2187 Fax (510) 490-1507
www.temcotransformer.com
Euro Standard Isolation Transformer
B
TT1202-TT1211
E
C
DA
Approximate dimensions given in inches
A B C D E lbs
112.5 kVA 23 1/8
30 3/4
31 3/4
25
37 1/2
750
150 kVA 23 1/8
30 3/4
31 3/4
25
37 1/2
900
225 kVA 23 3/4
40
46
29
39 1750
300 kVA 23 3/4
40
46
29
39 2000
500 kVA
36
46 64 1/2 30
50 2900
750 kVA
45
60
69 30
55 3800
Corporate Headquarters:
TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538
Inside USA (800) 613-2290 International (510) 490-2187 Fax (510) 490-1507
www.temcotransformer.com
.