Document
MCC
omponents 21201 Itasca Street Chatsworth
!"# $
% !"#
MB3505 THRU MB3510
Features
• Mounting Hole For #8 Screw • High Conductivity Metal Case • Any Mounting Position • Surge Rating Of 400 Amps
35 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
Maximum Ratings
• Operating Temperature: -55°C to +125°C • Storage Temperature: -55°C to +150°C
MCC Catalog Number
MB3505 MB351 MB352 MB354 MB356 MB358 MB3510
Device Marking
MB3505 MB351 MB352 MB354 MB356 MB358 MB3510
Maximum Recurrent Peak Reverse Voltage
50V 100V 200V 400V 600V 800V 1000v
Maximum RMS
Voltage
35V 70V 140V 280V 420V 560V 700V
Maximum DC
Blocking Voltage
50V 100V 200V 400V 600V 800V 1000v
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current
IF(AV)
35.0A TC = 55°C
Peak Forward Surge Current
IFSM
400A 8.3ms, half sine
Maximum Forward
Voltage Drop Per Element
VF 1.2V IFM = 17.5A per element;
Maximum DC
TJ = 25°C
Reverse Current At IR 10µA TJ = 25°C
Rated DC Blocking
1mA TJ = 125°C
Voltage
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
MB-35
B
C
E
G AC +
D HA - AC
J A
DIMENSIONS
INCHES
DIM MIN
MAX
A
1.115
1.135
B .427 .447
C .428 .468
D .688 .730
E .618 .658
G .193
---
H .618 .658
J .530 .570
MM MIN 28.33 10.85 10.87 17.48 15.70 4.90 15.70 13.46
MAX 28.83 11.35 11.89 18.50 16.71
--16.71 14.48
NOTE ∅
www.mccsemi.com
MB3505 thru MB3510
Figure 1 Typical Forward Characteristics
100 60 40
20 10 6
4
2 Amps 1
.6 .4
25°C
.2
.1 .06 .04
.02
.01 .2 .4 .6 .8 1.0 1.2 1.4
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts
Figure 3 Forward Derating Curve 60
50
40
30 Amps
20
10 Single Phase, Half Wave 60Hz Resistive or Inductive Load
00 25 50 75 100 150 175
°C
Average Forward Rectified Current - Amperesversus Case Temperature -°C
MCC
Figure 2 Typical Reverse Characteristics
10
6
4
2
1 .6 .4
.2 µAmps .1
TJ=25°C
.06
.04
.02
.01 .006 .00
4 .002 .001
20 40 60 80 100 120 140
Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts
Figure 4 Peak Forward Surge Current 600
500
400
300 Amps
200
100
0 12
4 6 8 10 20 Cycles
40 60 80 100 00
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
.