Document
AC-DC Power Supplies Enclosed type
Ordering information
PBA10FPPBBAA//PPBW
PB A 10 F -O -O
123456
R
Recommended EMI/EMC Filter NAC-06-472
1Series name 2Single output 3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G :Low leakage current
High voltage pulse noise type : NAP series Low leakage current type : NAM series
*The EMI/EMC Filter is recommended *to connect with several devices.
E :Low leakage current and EMI class A
T :Vertical terminal block J :Connector type
N :with Cover
(UL508 is acquired)
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT
PBA10F-5 10 5V 2A
PBA10F-12 10.8 12V 0.9A
PBA10F-24 12 24V 0.5A
SPECIFICATIONS
MODEL
PBA10F-5
PBA10F-12
PBA10F-24
VOLTAGE[V]
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
CURRENT[A]
ACIN 100V 0.30typ (Io=100%) ACIN 200V 0.20typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
INPUT
EFFICIENCY[%]
ACIN 100V 74typ ACIN 200V 74typ
76typ 76typ
77typ 77typ
INRUSH CURRENT[A]
ACIN 100V ACIN 200V
15typ (Io=100%) 30typ (Io=100%)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
5
12 24
CURRENT[A]
2
0.9 0.5
LINE REGULATION[mV] *6 20max
48max
96max
LOAD REGULATION[mV] *6 40max
100max
150max
RIPPLE[mVp-p]
0 to +50C*1 80max -10 - 0C*1 140max
120max 160max
120max 160max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1 -10 - 0C*1
120max 160max
150max 180max
150max 180max
TEMPERATURE REGULATION[mV]
0 to +50C -10 to +50C
50max 60max
120max 150max
240max 290max
DRIFT[mV]
*2 20max
48max
96max
START-UP TIME[ms]
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50
10.0 - 13.2
19.2 - 27.0
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15
12.00 - 12.48
24.00 - 24.96
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
PROTECTION CIRCUIT AND OTHERS
OVERVOLTAGE PROTECTION[V] OPERATING INDICATION
5.75 - 7.00 LED (Green)
15.0 - 18.0
REMOTE ON/OFF
None
30.0 - 37.0
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
NOISE
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4) *7
OTHERS
CASE SIZE/WEIGHT COOLING METHOD
31X78X68mm [1.22X3.07X2.68 inches] (without terminal block) (WXHXD) / 150g max (with cover : 180g max) Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Derating is required. *4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5 Please contact us about safety approvals for the model with option. *6 Please contact us about dynamic load and input response. *7 Please contact us about class C. * Parallel operation with other model is not possible. * Derating is required when operated with cover. * A sound may occur from power supply at peak loading.
PBA/PBWW--22
Block diagram
PBA10F
AC IN 85 - 264V
FUSE AC250V
2.5A
NOISE FILTER
INRUSH CURRENT
LIMIT
RECTIFIER AND
FILTER
FG
CONTROL
INVERTER
TRANSFORMER RECTIFIER AND FILTER
CURRENT SENSING
Photocoupler
CONTROL
Photocoupler
OVER VOLTAGE PROTECTION
PBA/PBW
DC OUT
External view
¶ External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
Voltage adjust
18 [0.71] 12.2 ±1.5 [0.48]
2.5 LED [0.1]
Cover name plate
16.5±2 [0.65]
68 [2.68]
70.5 [2.78] 11.5 9.5 7.5 [0.45] [0.37] [0.3]
+V -V FG AC(L) AC(N)
15.1±1.5 [0.59] 22.6±1.5 [0.89]
M3 Cover (option)
Terminal cover
2-M3 Mounting hole
78 [3.07]
34.5 [1.36]
49.5±0.5 [1.95]
4 [0.16] Point A:C102
Name plate
2-M3 Mounting hole
18 [0.71] 31
[1.22] 34.5 [1.36]
¶ Tolerance : ±1 [±0.04] ¶ Weight : 150g max (with cover : 180g max) ¶ PCB Materia.