Document
MCC
Features
• Mounting Hole For #8 Screw • Plastic Case With Metal Bottom • Any Mounting Position • Surge Rating Of 300 Amps
!"# $
% !"#
MP2505 THRU MP2510
25 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
Maximum Ratings
• Operating Temperature: -55°C to +150°C • Storage Temperature: -55°C to +150°C
MP-50
B
MCC Catalog Number
MP2505 MP251 MP252 MP254 MP256 MP258 MP2510
Device Marking
MP2505 MP251 MP252 MP254 MP256 MP258 MP2510
Maximum Recurrent Peak Reverse
Voltage 50V 100V 200V 400V 600V 800V 1000v
Maximum RMS
Voltage
35V 70V 140V 280V 420V 560V 700V
Maximum DC
Blocking Voltage
50V 100V 200V 400V 600V 800V 1000v
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element
Maximum DC Reverse Current At Rated DC Blocking Voltage
IF(AV) IFSM VF
IR
25.0A 300A
TC = 55°C 8.3ms, half sine
1.1V
IFM = 12.5A per element;
TJ = 25°C
5µA TJ = 25°C 500uA TJ = 125°C
I2t Rating for Fusing t<8.3mS
2
It
375
A2 S
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
C
E
G AC +
D HA - AC
J A
DIMENSIONS
INCHES
DIM MIN
MAX
A 1.118 1.130
B .432 .442
C .468 .558
D .689 .728
E .618 .657
G .193
---
H .618 .657
J .531 .571
MM MIN 28.40 10.97 11.89 17.50 15.70 4.90 15.70 13.50
MAX 28.70 11.23 14.17 18.50 16.70
--16.70 14.50
NOTE ∅
www.mccsemi.com
MP2505 thru MP2510
Figure 1 Typical Forward Characteristics
100 60 40
20 10 6
4
2 Amps 1
.6 .4
25°C
.2
.1 .06 .04
.02
.01 .2 .4 .6 .8 1.0 1.2 1.4
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts
Figure 3 Forward Derating Curve 30
25
20
15 Amps
10
5 Single Phase, Half Wave 60Hz Resistive or Inductive Load
00 25 50 75 100 150 175
°C
Average Forward Rectified Current - Amperesversus Case Temperature -°C
MCC
Figure 2 Typical Reverse Characteristics
10
6 4
2
1 .6 .4
.2 µAmps .1
TJ=25°C
.06
.04
.02
.01 .006 .00
4 .002 .001
20 40 60 80 100 120 140
Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts
Figure 4 Peak Forward Surge Current 300
250
200
150 Amps
100
50
0 12
4 6 8 10 20 Cycles
40 60 80 100 00
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
.