Single 10Base-T/100Base-TX Transformer
YCL
Single 10Base-T/100Base-TX Transformer Design for varied turn ratio on Tx side
♦Designed to meet IEEE802.3u requir...
Description
YCL
Single 10Base-T/100Base-TX Transformer Design for varied turn ratio on Tx side
♦Designed to meet IEEE802.3u requirement.
♦Primary inductance 350µH min. with 8mA DC Bias
♦Miniature SMT type ♦Pick and Place compatible
Electrical Characteristic @25°C
Model No.
Turn Ratio TX/RX
PH163112
1:1/1:1
PH163113 1.414:1/1:1
PH163114
2:1/1:1
PH163115 1.25:1/1:1
Note : Greater than 16-20 log(f/30MHz)
Insertion Loss dB Typ
0.1-100MHz
1.0
1.0
1.0 1.0
Return Loss dB
30/60/80MHz
-16/note/-10
-16/note/-10
-16/note/-10 -16/note/-10
Dimension
Schematic
Cross Talk dB Typ
60/100MHz
-40/-38
-40/-38
-40/-38 -40/-38
P=1.27*7=8.8
1 TX 2
3
6 RX 7
8
16 15 14
11 10 9
Date : Jan.03,2000
...