Relay
SONGLE RELAY
www.datasheet4u.com
RELAY ISO9002
SLA
1. MAIN FEATURES
ᄋ Up to 30A switching in SPST and 20A switching...
Description
SONGLE RELAY
www.datasheet4u.com
RELAY ISO9002
SLA
1. MAIN FEATURES
ᄋ Up to 30A switching in SPST and 20A switching in spot
arrangements.
ᄋ Available as an open-frame relay,
with a snap-on dust cover or with an immersion cleanable,
plastic sealed case.
2. APPLICATIONS
ᄋ Used for power switching, Electrical Heater, ventilator,
Air conditioning,
3. ORDERING INFORMATION
SLA
XX VDC
Refrigerating, Automobile and House-hold Appliance. SLC
Model of relay SLA
Nominal coil voltage
05 06 09 12 18 24 48 110VDC
Structure S:Sealed type F:Flux free type
Coil sensitivity L:0.93W D:Special
Contact form A:1 form A
B:1 form B C:1 form C
4. RATING
20A/28VDC 250VAC 30A/30VDC 250VAC
CCC
FILE NUMBER:CQC03001003728 30A/250VDC
UL/CUL FILE NUMBER: E179944
NO:20A/240VAC 28VDC NC:10A/240VAC 28VDC
TUV
FILE NUMBER: R50056114
NO:30A/250VAC 30VDC NC:20A/250VAC 30VDC
5. DIMENSION(unit:mm)
DRILLING(unit:mm)
WIRING DIAGRAM
1
6. COIL DATA CHART (AT20 ö C)
Coil Sensitivity
Coil Voltage Code
Nominal Voltage (VDC)
Nominal Current
(mA)
www.datasheet4u.com
05
5
185
06 6 150
09 9
93
12 12 77 SLA 15 15 59
18 18 47
24 24 36
48 48
20
110 110
9
Coil Power
Resistance Consumption
(Ω) ᄋ10%
(W)
27 40 97
155 abt. 0.93W 256 380
660 2480
13000
Pull-In Voltage (VDC)
75% Max.
Drop-Out Voltage (VDC)
10% Max.
Max-Allowable Voltage (VDC)
120%Max.
7. CONTACT RATING
Type
SLA
Item
FORM A
FORM B
FORM C N/O N/C
Resistive Load
(cosΦ=1) General Motor
30A 250VAC 30A 3...
Similar Datasheet