H S TSol503 Temperature Controller for Thermic Solar Panel Systems GB Pag. 1 / 12 TSol503 Manual V1.0 1 Introduction Main The Controller TSol503 is for the management of Solar Plants with Natural and Forced Circulation with a Solar Panel, Accumulation/Boiler/Pool, Integration and Systems of Protection/Cooling Safety regulations Read carefully the following safety regulations, in order to prevent damages and danger to people and things. Before working on plants, follow • Accident prev.

  TSol503   TSol503


Document
H S TSol503 Temperature Controller for Thermic Solar Panel Systems GB Pag. 1 / 12 TSol503 Manual V1.0 1 Introduction Main The Controller TSol503 is for the management of Solar Plants with Natural and Forced Circulation with a Solar Panel, Accumulation/Boiler/Pool, Integration and Systems of Protection/Cooling Safety regulations Read carefully the following safety regulations, in order to prevent damages and danger to people and things. Before working on plants, follow • Accident prevention measures • Environmental protection measures • National Institute for Work accidents measures • Recognized prevention measure • Directions are only for technical staff • Electrical works must be done only by qualified technicians • The first installation of the plant must be done by expert personal or by the builder Declaration of Conformity: Rules: EN 60730-1 50081-1 EN 60730-1 A1 50081-2 TiEmme elettronica 06055 Marsciano (PG) Italy Tel. +39.075.874.3905; Fax. +39.075.874.2239 [email protected] Product composition N. 01 TSol503 Technical data Supply: 230 Vac 50 Hz N. 04 screws and plugs Input: 2 VA N. 02 screws for controller’s fixing Capacity: 5A 250 Vac N. 01 Box Internal fuse: 3,15 A N. 01 Plate Protection grade: IP40 N. 01 Kit Probe PT1000 Reading probes: PT1000 Measure Range: -40 ÷ 300 °C Installing and Use Conditions Mechanical Characteristics Functioning temperature: 0 ÷ 40 °C Material: ABS Plastic Storage temperature: 0 ÷ 60 °C Installing: Wall / Panel Humidity: 85% @25°C Dimension: 160 x 90 x 58 mm Display: Graphic Backlight 128x64 2 Installation 2.1 Installing Before doing any operation make sure that the Main Power Supply is OFF FF HH HH PL F CC CC CC CC CC CC F CC CC P VV VV VV VV VV Cx8 V x5 H x2 Fig. 1. Components Pag. 2 / 12 TSol503 Manual V1.0 • Install TSol503 only in dry ambient and in correct climatic conditions • Fix the Box with fixing points F • Take away the lid that cable-block P • Insert the connecting cables through cablethrough C that are in the points CC of the Box • The box has 8 outputs for the cables: if more inputs are necessary USE multipolar cables but put together only cables of the same type • Do the electrical connections • Put the controller in the Box and put the cable in order to facilitate the insertion • Block cable through the cable-block P with screws V in points VV • Fix the controller through screws H in points HH • Insert the plate PL 2.2 Electrical Connections For a correct and safe functioning make always the electrical connections to earth Make ordered connections and separate low tension signals (probes, contacts, cables of the control board) from high tension signals (supply, loads) to reduce interference problems S1 S2 S3 Probes PT1000 P3 P4 Supplied outputs 230 Vac P5 In Exchange Contacts Output 1 2 3 4 5 6 7 8 9 10 11 12 13 N.O. N.C. COM LN LINE 230 Vac Lo N Lo N P3 P4 P5 14 15 16 17 18 19 S1 S2 S3 Fig. 2. Electrical Connections 3 Probes Installation TSol503 manages temperature probes PT1000. The reading range is -40 ÷ 300°C with precision of 1°C. If the probe is in short-circuit the display shows “Short” If the probe is unconnected or broken the display shows “Open”. • The probe’s range depends on the declared probe’s characteristics. TiEmme elettronica is not responsible for damages or malfunctioning of the probe that are due to a use of it out of the range or due to a break of the cable. • The installing of the cables must be separated by the high tension cables like supply, pump commands, valves, in order to avoid interference problems during the temperature reading. • Probes can be extended with a 2 x 1 mm cable until 30 mt • Use the shielded cable in case of interference in the temperature reading. 4 KeyBoard Use and Functions Button’s functions: P1 P2 P3 S Lun T11=08.30°0 H P4 P4/P6=Run Menu Values Increase/decrease P3= Enter in Menu P5 Save in Menu P1= Exit Menu P6 P5= Probes’ Temperature / Special Function Fig. 3. LCD Panel Pag. 3 / 12 TSol503 Manual V1.0 4.1 Display Pump: ON if Blinking S Panel Protection : ON if Blinking H Holiday: Function Activated if present Cooling Circuit Pool Valve: Flux Direction Integration Boiler: ON if Blinking Alarm/s in Course Exchanger with Plates With button P4 enter menu “Monitor” to consult the current ALARM states and other information Sys 1 =Plant Number Monitor Sys 1 Probe Temperature T1 = 70 Probe in short circuit T2 = Short Unconnected Probe or Broken T3 = Open Fig. 4. Monitor Menu With button P4 enter menu “Statistics” to consult the current ALARM states and other information Sys 1 = Plant Number Statistics Sys 1 Alarms read Alarm Code A02 Other possible information Fig. 5. Statistics Menu 4.2 Allarmi DESCRIPTION Collector’s over-temperature: temperature on S1 more than Thermostat THS103 Boiler’s over-temperature: Temperature on S2 more than Thermostat THS203 Collector’s De-Ice: temperature on S1 less then .


K612 TSol503 Y35KPC


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)