H S
TSol503
Temperature Controller for Thermic Solar Panel Systems
GB
Pag. 1 / 12
TSol503 Manual V1.0
1 Introduction
Main
The Controller TSol503 is for the management of Solar Plants with Natural and Forced Circulation with a
Solar Panel, Accumulation/Boiler/Pool, Integration and Systems of Protection/Cooling
Safety regulations
Read carefully the following safety regulations, in order to prevent damages and danger to people and
things.
Before working on plants, follow
• Accident prevention measures • Environmental protection measures • National Institute for Work accidents measures • Recognized prevention measure • Directions are only for technical staff • Electrical works must be done only by qualified technicians • The first installation of the plant must be done by expert personal or by the builder Declaration of Conformity: Rules:
EN 60730-1 50081-1 EN 60730-1 A1 50081-2
TiEmme elettronica
06055 Marsciano (PG) Italy
Tel. +39.075.874.3905; Fax. +39.075.874.2239
[email protected]
Product composition N. 01 TSol503
Technical data Supply:
230 Vac 50 Hz
N. 04 screws and plugs
Input:
2 VA
N. 02 screws for controller’s fixing
Capacity:
5A 250 Vac
N. 01 Box
Internal fuse:
3,15 A
N. 01 Plate
Protection grade: IP40
N. 01 Kit Probe PT1000
Reading probes: PT1000
Measure Range: -40 ÷ 300 °C
Installing and Use Conditions
Mechanical Characteristics
Functioning temperature:
0 ÷ 40 °C
Material:
ABS Plastic
Storage temperature:
0 ÷ 60 °C
Installing:
Wall / Panel
Humidity: 85% @25°C
Dimension:
160 x 90 x 58 mm
Display:
Graphic Backlight 128x64
2 Installation
2.1 Installing
Before doing any operation make sure that the Main Power Supply is OFF
FF
HH HH
PL
F
CC CC
CC CC
CC CC
F
CC CC
P
VV VV VV VV VV
Cx8 V x5 H x2
Fig. 1. Components
Pag. 2 / 12
TSol503 Manual V1.0
• Install TSol503 only in dry ambient and in correct climatic conditions • Fix the Box with fixing points F • Take away the lid that cable-block P • Insert the connecting cables through cablethrough C that are in the points CC of the Box • The box has 8 outputs for the cables: if more inputs are necessary
USE multipolar cables but put together only cables of the same type • Do the electrical connections • Put the controller in the Box and put the cable in order to facilitate the insertion • Block cable through the cable-block P with screws V in points VV • Fix the controller through screws H in points HH • Insert the plate PL
2.2 Electrical Connections
For a correct and safe functioning make always the electrical connections to earth Make ordered connections and separate low tension signals (probes, contacts, cables of the control board) from high tension signals (supply, loads) to reduce interference problems
S1 S2 S3 Probes PT1000
P3 P4 Supplied outputs 230 Vac
P5 In Exchange Contacts Output
1 2 3 4 5 6 7 8 9 10 11 12 13
N.O. N.C. COM
LN
LINE
230 Vac
Lo N Lo N
P3 P4 P5
14 15 16 17 18 19
S1 S2 S3
Fig. 2. Electrical Connections
3 Probes Installation
TSol503 manages temperature probes PT1000. The reading range is -40 ÷ 300°C with precision of 1°C. If the probe is in short-circuit the display shows “Short” If the probe is unconnected or broken the display shows “Open”. • The probe’s range depends on the declared probe’s characteristics.
TiEmme elettronica is not responsible for damages or malfunctioning of the probe that are due to a use of it out of the range or due to a break of the cable. • The installing of the cables must be separated by the high tension cables like supply, pump commands, valves, in order to avoid interference problems during the temperature reading. • Probes can be extended with a 2 x 1 mm cable until 30 mt • Use the shielded cable in case of interference in the temperature reading.
4 KeyBoard Use and Functions
Button’s functions:
P1 P2
P3
S
Lun T11=08.30°0 H
P4 P4/P6=Run Menu Values Increase/decrease
P3= Enter in Menu P5 Save in Menu
P1= Exit Menu P6 P5= Probes’ Temperature / Special Function
Fig. 3. LCD Panel
Pag. 3 / 12
TSol503 Manual V1.0
4.1 Display
Pump: ON if Blinking
S Panel Protection : ON if Blinking H Holiday: Function Activated if present
Cooling Circuit
Pool
Valve: Flux Direction Integration Boiler: ON if Blinking Alarm/s in Course Exchanger with Plates
With button P4 enter menu “Monitor” to consult the current ALARM states and other information
Sys 1 =Plant Number
Monitor
Sys 1
Probe Temperature
T1 = 70
Probe in short circuit
T2 = Short
Unconnected Probe or Broken
T3 = Open
Fig. 4. Monitor Menu
With button P4 enter menu “Statistics” to consult the current ALARM states and other information
Sys 1 = Plant Number
Statistics
Sys 1
Alarms read
Alarm Code
A02
Other possible information
Fig. 5. Statistics Menu
4.2 Allarmi
DESCRIPTION Collector’s over-temperature: temperature on S1 more than Thermostat THS103
Boiler’s over-temperature: Temperature on S2 more than Thermostat THS203
Collector’s De-Ice: temperature on S1 less then .