Bi-Directional Coupler
High Power
Bi-Directional Coupler
50Ω Up to 100W 0.4 to 15 MHz
ZABDC50-150HP+
Maximum Ratings
Operating Temperature
...
Description
High Power
Bi-Directional Coupler
50Ω Up to 100W 0.4 to 15 MHz
ZABDC50-150HP+
Maximum Ratings
Operating Temperature
-55°C to 75°C
Storage Temperature
-55°C to 100°C
Permanent damage may occur if any of these limits are exceeded.
Coaxial Connections
INPUT OUTPUT COUPLED (forward) COUPLED (reverse)
1 (N-Type) 4 (N-Type)
2 (SMA) 3 (SMA)
Outline Drawing
Features
good coupling flatness, 0.5 dB typ. high directivity, 30 dB typ. excellent VSWR, 1.03:1 typ. high power, up to 100W extremely low insertion loss, 0.01 dB typ.
Applications
HF radios AM radio, amateur radio, medical ultrasound
CASE STYLE: HHH141
Connectors Model
Price
N-Type/SMA ZABDC50-150HP+ $89.95
Qty. (1-9)
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications
Parameter Frequency Range Mainline Loss Coupling Coupling Flatness(±) Directivity Return Loss (Input) Return Loss (Output) Return Loss (Coupling) Input Power
Electrical Specifications at 25°C
Condition (MHz)
Min.
Typ.
0.4 —
0.4-15
— 0.01
0.4-15
49 50
0.4-15
— 0.5
0.4-15
20 30
0.4-15
22 33
0.4-15
22 33
0.4-15
27 36
——
Max. 15 0.1 51.5 — — — — — 100
Unit MHz dB dB dB dB dB dB dB W
Outline Dimensions ( imncmh)
ABCD 2.00 2.00 .95 1.062 50.80 50.80 24.13 26.97
EF .125 1.75 3.18 44.45
Frequency (MHz)
0.40 1.00 2.00 3.00 4.00 5.00 6.00 8.00 10.00 15.00
Mainline Loss (dB)
Typical Performance Data
Coupling (dB)
Directivity (dB)
In-Out