Pre-amplified/5V Excitation/Gauge
XFPM Data sheet
■Features
On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Dual-in-line package (DIP)
■Ordering Information XFPM-025KP G R
Model
Terminal leadsdirection No Mark:
Rated Pressure KP:kPa
MP:MPa
Pressure type G:Gauge(Positive pressure)
R:
GV:Gauge Pressure(Negative pressure)
GW:Gauge Pressure(Positive/Negative pressure)
Weight
(grams)
RoHS compliance
1.2
Measurable pressure range(kPa)
-100 to 100 0 to -100 0 to 25 0 to 50 0 to 100 0 to 200 0 to 1000
Part number
XFPM-100KPGW XFPM-100KPGV XFPM-025KPG XFPM-050KPG XFPM-100KPG XFPM-200KPG XFPM-001MPG
XFPM-100KPGWR XFPM-100KPGVR XFPM-025KPGR XFPM-050KPGR XFPM-100KPGR XFPM-200KPGR XFPM-001MPGR
■Specifications
Model
100KPGW 100KPGV 025KPG 050KPG 100KPG 200KPG 001MPG
Recommended operating conditions
Pressure type
Gauge pressure
Rated pressure
+/-100
-100
25
50 100 200 1000
Measurable pressure range -100 to100 0 to -100 0 to 25 0 to 50 0 to 100 0 to 200 0 to 1000
Temperature range
0 to 85
Pressure media
Non-corrosive gases only (No liquid)
Supply voltage(constant)
5+/-0.25
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
1.5 times of rating pressure
Maximum excitation voltage
8
Operating temperature
-40 to 125
Storage temperature
-40 to 125
Operating humidity
30 to 80 (Non dew condition)
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25deg.C)
Power consumption
10mA max.
Output impedance
10Ω max.
Source current
0.2mA max.
Sink current
2mA max.
Response time
2 (for the reference)
Output span voltage
4.5
Offset voltage *1
*2 *3
0.2+/-0.1125 (at 0 kPa )
Output voltage at full scale *1
*4
*5
4.7+/-0.1125 (at rated pressure)
Accuracy *1
+/-2.5
*1 Excluding input voltage error. 0-85deg.C *2 0.2+/-0.1125V(at -100kPa ) *3 0.2+/-0.1125V(at 0kPa) *4 4.7+/-0.1125V(at +100kPa) *5 4.7+/-0.1125V(at -100kPa)
Unit
kPa kPa deg.C
VDC
-
VDC deg.C deg.C %RH
mA Ω mA mA msec. V V V
%FS/0-85deg.C
1
Pre-amplified/5V Excitation/Gauge
■Outline dimensions■
XFPM Data sheet
2
Pre-amplified/5V Excitation/Gauge
■Connection diagram■
View from Lavel
XFPM Data sheet
Marking
■Transfer Function■
Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs)
Vs=Vcc=5.0V
P=Input pressure(kPa)
Model
XFPM-100KPGW XFPM-100KPGV XFPM-025KPG XFPM-050KPG XFPM-100KPG XFPM-200KPG XFPM-001MPG
XFPM-100KPGWR XFPM-100KPGVR XFPM-025KPGR XFPM-050KPGR XFPM-100KPGR XFPM-200KPGR XFPM-001MPGR
Measurable pressure
range(kPa) -100 to 100
0 to -100 0 to 25 0 to 50 0 to 100 0 to 200 0 to 1000
α
0.0045 -0.009 0.036 0.018 0.009 0.0045 0.0009
Temperature Error Multiplier
β
Pressure Error (kPa)
0.49 5 0.04 2.5 0.04 0.625 0.04 1.25 0.04 2.5 0.04 5 0.04 25
3
Pre-amplified/5V Excitation/Gauge
XFPM Data sheet
■Output characteristics■
XFPM-100KPGV XFPM-025KPG XFPM-050KPG XFPM-100KPG XFPM-200KPG XFPM-001MPG
XFPM-100KPGVR XFPM-025KPGR XFPM-050KPGR XFPM-100KPGR XFPM-200KPGR XFPM-001MPGR
↑Output voltage(mV)
Output voltage at full scale
4.7V
Offset voltage
0.2V 0kPa Atomospheric pressure
Output span voltage
Rated pressure
→Pressure(kPa)
XFPM-100KPGW XFPM-100KPGWR
↑Output voltage(mV)
Output voltage at full scale
4.7V Offset voltage
Output span voltage
0.2V
-100kPa 0kPa
Atomospheric pressure
+100kPa
→Pressure(kPa)
Note ;
Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag. If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using.
If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail :
[email protected]