THT CURRENT SENSE TRANSFORMERS/INDUCTORS
THT CURRENT SENSE TRANSFORMERS & INDUCTORS
DVE VDE Approved Designed for switching power supply applications Transforme...
Description
THT CURRENT SENSE TRANSFORMERS & INDUCTORS
DVE VDE Approved Designed for switching power supply applications Transformer meets IEC950 insulation requirements Frequency range from 20kHz to 200kHz
Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C
Part Number Transformer
with 2-1 T Primaries
Schem. Figure
Part Number Transformer Schem.
with 1T Figure Primary
Part Number Inductor without Primary
Schem. Figure
Turns NS
—
1C PE-63586 1A PE-51686 2A
50
PE-64487 1C PE-63587 1A PE-51687 2A
100
PE-64488 1C PE-63588 1A PE-51688 2A
200
PE-64517 1D — — PE-51717 2B 50CT
PE-64518 1D PE-63618 1B PE-51718 2B 100CT
PE-64519 1D PE-63619 1B PE-51719 2B 200CT
—
— PE-63691 1B
—
— 300CT
NOTES: 1. Maximum ratings specified with rated secondary terminating resistance
and 1 turn primary. 2. Amp-microsecond (AµSec.) rating of primary equals volt microsecond
(VµSec.) rating of secondary when secondary is terminated in rated resistance. (Amp—microseconds is equal to the product of a square pulse of current in amps, times the current pulse width in microseconds. 3. Maximum operating temperature 105°C (ambient plus rise).
Secondary Inductance
MH (MIN)
5.0
20.0
80.0
5.0
20.0
80.0 180.0
Secondary Inductance Test Voltage (15.75 KHz)
0.5
1.0
2.0
0.5
1.0
2.0 3.0
RS (Ω MAX)
0.7 1.40 4.50 0.7 1.40 4.50 11.0
RT (Ω NOM)
50 100 200 50 100 200 300
Primary Unipolar Amp µ Sec. Rating (MAX)
150
300
600
150
300
600 900
Primary Bipolar Amp µ Sec. Rating (MAX)
300
600
1200...