INDUCTORS October 2013 Inductors for Power Circuits Wound Ferrite CLFseries CLF6045 CLF7045 CLF10040 CLF12555 INDUCTORS REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. (2/21) REMINDERS The storage period is less than 6 months. Be sure to follow the storage conditions (Temperature: 5 to 30°C, Humidity: 10 to 75% RH or le.

  CLF12555   CLF12555


Document
INDUCTORS October 2013 Inductors for Power Circuits Wound Ferrite CLFseries CLF6045 CLF7045 CLF10040 CLF12555 INDUCTORS REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. (2/21) REMINDERS The storage period is less than 6 months. Be sure to follow the storage conditions (Temperature: 5 to 30°C, Humidity: 10 to 75% RH or less). If the storage period elapses, the soldering of the terminal electrodes may deteriorate. Do not use or store in locations where there are conditions such as gas corrosion (salt, acid, alkali, etc.). Before soldering, be sure to preheat components. The preheating temperature should be set so that the temperature difference between the solder temperature and chip temperature does not exceed 150°C. Soldering corrections after mounting should be within the range of the conditions determined in the specifications. If overheated, a short circuit, performance deterioration, or lifespan shortening may occur. When embedding a printed circuit board where a chip is mounted to a set, be sure that residual stress is not given to the chip due to the overall distortion of the printed circuit board and partial distortion such as at screw tightening portions. Self heating (temperature increase) occurs when the power is turned ON, so the tolerance should be sufficient for the set thermal design. Carefully lay out the coil for the circuit board design of the non-magnetic shield type. A malfunction may occur due to magnetic interference. Use a wrist band to discharge static electricity in your body through the grounding wire. Do not expose the products to magnets or magnetic fields. Do not use for a purpose outside of the contents regulated in the delivery specifications. The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition. The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person or property. If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions set forth in the each catalog, please contact us. (1) Aerospace/Aviation equipment (2) Transportation equipment (cars, electric trains, ships, etc.) (3) Medical equipment (4) Power-generation control equipment (5) Atomic energy-related equipment (6) Seabed equipment (7) Transportation control equipment (8) Public information-processing equipment (9) Military equipment (10) Electric heating apparatus, burning equipment (11) Disaster prevention/crime prevention equipment (12) Safety equipment (13) Other applications that are not considered general-purpose applications When designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing protection circuit/device or providing backup circuits in your equipment. 001-01 / 20131023 / inductor_commercial_power_clf_en.fm INDUCTOR Inductors for Power Circuits Wound Ferrite S (3/21) Product compatible with RoHS directive Compatible with lead-free solders Overview of the CLF Series FEATURES Magnetic shield type wound inductor for power circuits. 1 to 470µH, wide E-6 Series lineup allows for various usages. APPLICATION Thin-screen TVs, LCDs, AV equipment, STBs, LED lights, industrial equipment PART NUMBER CONSTRUCTION CLF 7045 T - 1R5 Series name L×W×H Dimensions (mm) 6045 6.2×5.9×4.5 7045 7.2×6.9×4.5 10040 10.0×9.7×3.8 12555 12.5×12.1×5.5 Packaging style T Taping Inductance (µH) 1R0 1.0 100 10 101 100 N Inductance tolerance M ±20% N ±30% OPERATING TEMPERATURE RANGE, PACKAGE QUANTITY, PRODUCT WEIGHT Temperature range Type Operating temperature Storage temperature Package quantity °C °C (pieces/reel) CLF6045 –40 to +105 –40 to +105 1000 CLF7045 –40 to +105 –40 to +105 1000 CLF10040 –40 to +105 –40 to +105 800 CLF12555 –40 to +105 –40 to +105 500 Operating temperature range includes self-temperature rise. The Storage temperature range is for after the circuit board is mounted. Individual weight g 0.6 0.8 1.3 3.0 RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://www.tdk.co.jp/rohs/ • All specifications are subject to change without notice. 001-01 / 20131023 / inductor_commercial_power_clf_en.fm INDUCTORS Overview of the CLF Series T: Temperature RECOMMENDED REFLOW PROFILE Preheating Soldering Peak T4 Natural co.


CLF10040 CLF12555 BM6209FS


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)